Renewing impulse switch on wiper motor model 114, 115
WIS 82-685
Impulse transmitter made by Bosch
Removal
1 Remove wiper motor (82—680).
2 Mark crank position in relation to shaft, loosen nut and remove crank (1).
1 Crank 2. Fastening plate 3 > Wiper motor 182-8394
3 Unscrew screws of fastening plate (2) and remove fastening plate.
4 Unscrew angle bracket of impulse switch (4).
Attention!
Do not pull out plug plate (5), since the peening in cast housing (arrows) may break out. The plug plate will then lose its hold.
5 Unsolder the following lines on back of plug plate (5): line “black on plug pin No. 6”, line white on plug pin No. 3”, line ‘‘brown on plug pin No. 1”.
motor, strip line ends and coat with tin.
3 Wiper motor 4 Impulse switch gn green lines rt red lines
7 Unsolder yellow, grey and blue lines from the three soldering lugs of insulating member (6).
8 Cut red and green lines (’”B and D”’) of new impulse switch to approx. 70 mm length, strip ends and coat with tin.
6 Insulating member 7 Gear housing on wiper motor
Impulse switch
9 Slip one insulating hose each 40 mm long over red and green lines leading into wiper motor. Then insert these lines into one soldering sleeve each (tubular rivet A 3 x 0.25 x 10, DIN 7340 MS) and solder to respective lines ‘’B” and ”D”’ of impulse switch. Then slip insulating hoses over soldering sleeves.
switch to soldering lugs. Make sure that the grounding wire is additionally soldered to soldering lug I, and the dark green line additionally to soldering lug I.
11. Solder the black, white and brown lines of impulse switch as follows to back of plug plate:
black to plug pin No. 6 white to plug pin No. 3 brown to plug pin No. 1
Installation
12 Screw angle bracket with impulse switch as well as fastening plate to wiper motor.
13 If the mark of the former crank position is still visible, mount crank (1) accordingly. If not, run engine (3) into parking position and screw down crank.
Testing wiper motor prior to installation
14 Connect a positive and negative line to a 12-volt battery. Clamp positive line to plug pin No. 4, negative line to plug pin No. 5.
Connect another line to positive pole of battery and hold other end of this line successively to plug pins No. 1, 3 and 6.
Plug pin No. 1: circuit for slow Plug pin No. 2: circuit for fast Plug pin No. 6: circuit for interval
15 Mark crank position in relation to shaft, loosen nut and remove crank (1).
16 Unscrew screws of fastening plate (2) and remove fastening plate.
17. After opening peening, remove impulse switch (4) from guides.
18 Slip insulating hoses over soldering sleeves of red and green lines and flush soldering sleeves.
19 Unsolder brown, yellow and black lines on soldering lugs of insulating member (7), remove grounding connection (8).
6 Gear housing on wiper motor 7 Insulating member 8 Ground connection br brown ge yellow sw black
impulse switch to soldering lugs of insulating member and screw on grounding connection.
21 Solder red and green lines of new impulse switch to respective lines of wiper motor and soldering sleeves. Then slip insulating hoses over soldering sleeves.
22 Slip impulse switch into guides of wiper motor. Mount fastening plate and screw on.
5 Insulating hoses gn green rt red
23 If the mark of the former crank position is still visible, mount crank accordingly. If not, adjust crank and screw down.
24 Test wiper motor prior to installation. Test similar to item 14.