Inspection of check valve
WIS 42-023
Data
Test vacuum in bar (ati) 0.75–0.8
Duration of test 30s
Pressure drop in bar vacuum (atii) 0.2
Special tool
Vacuum tester – 116 589 25 21 00
Self-made tool
Measuring connection refer to illustration item 2, note
Note Inspect check valve in vacuum line for leaks each time the brake unit is renewed.
Test procedure
1 Loosen vacuum line (3) on brake unit (1) and attach measuring connection (2) between brake unit and line.
2 Connect tester for vacuum (030) to measuring connection (2).
Note: The measuring connection is self-made according to dimensions shown in illustration. For Parts connection to the brake unit, the pipe elbow and including the coupling nut may be taken from an to old vacuum line. Connection to the vacuum line is made by means of a screw connection.
3 Run engine and establish vacuum of 0.75—0.8 bar (ati) by acceleration and sudden release of accelerator pedal.
4 Inspect check valve for leaks. The available vacuum should drop by no more than 0.2 bar (atii). If the drop in vacuum is higher, replace check valve including vacuum line.
Note: Repeat leak test upon installation of a new vacuum line. If the pressure drop is still too high, the leak may be the result of damaged screw connections or a leaking brake unit.