Removal and installation of ir immersion tube indicator
WIS 47-710
| A. Model 116 Tightening torque | Nm |
| Immersion tube indicator | 35–43 |
Removal
1 Remove first aid kit and first aid kit mounting shell (arrow).
2 Pull coupler (66) for fuel gage from immersion tube indicator (65) and protect with wire against slipping off.
3 Unscrew immersion tube indicator.
Note: Let immersion tube indicator run dry, if required.
Installation
4 For installation proceed vice versa, while proceeding as follows:
a) Use new rubber sealing ring.
b) Remove locking pin (arrow) prior to installing immersion tube indicator.
c) Check fuel gage for function.
d) Tighten immersion tube indicator to 35–43 Nm.
e) Plug-on coupler for fuel gage.
f) Check for leaks.
W7-10702
B. Model 123 T-sedan
Tightening torque Nm
Immersion tube indicator 35–43
1 Loosen trunk floor by turning tommy lock and remove.
2 Remove storage shelf.
3 Pull off coupler (66) for fuel gage and unscrew immersion tube indicator (65).
Note: Let immersion tube indicator run dry, if required.
Installation
4 For installation proceed vice versa as follows:
a) Use new rubber sealing ring.
b) Prior to installation of immersion tube indicator, remove locking pin (arrow).
c) Check fuel gage for function.
d) Tighten immersion tube indicator to 35–43 Nm.
e) Plug-on coupler for fuel gage.
f) Check for leaks.
C. Model 126
Tightening torque
Immersion tube indicator
Removal
1 Remove rear seat bench and backrest (refer to section covering body).
2 Remove filler cap.
3 Pull off coupler (66) and protect against slipping off.
4 Unscrew immersion tube indicator (65).
Note: Let immersion tube indicator run dry, if required.
Installation
5 For installation proceed vice versa as follows:
a) Use new rubber sealing ring.
b) Prior to inserting a new immersion tube indicator, remove locking pin (arrow).
c) Check fuel gage for function.
d) Tighten immersion tube indicator to 35–43 Nm.
e) Plug-on coupler for fuel gage.
f) Check for leaks.