Removal and installation of coolant pump housing
WIS 20-230
Tightening torques Nm
Model 116 6–10 Radiator drain plug _. Model 123, 126 1.5–2′)
Coolant pump housing to cylinder crankcase 27–33
Viscofan coupling to coolant pump 20–25
1) This torque can be obtained by means of a washer or a coin.
Special tools
Tester for cooling system – 001 589 48 21 00
paoiator cap with hose for ap x econ? – 605 589 00 25 00
Socket 27 mm, 1/2” square Cs – 001 589 65 09 00
7 mm socket on flexible shaft for hose clamps with worm drive – 123 589 12 09 00
Removal
1 Completely drain coolant (20—010).
2 Remove radiator (20—420).
3 Remove fan with viscofan coupling.
4 Slacken all V-belts and remove (13—340).
5 Remove coolant pump pulley.
6 Remove crankshaft pulley and vibration damper (03-340).
housing.
8 Disconnect hose between coolant thermostat housing and coolant pump housing.
9 Rotate crankshaft with too! combination until the recess in balancing disk is in front of lower fastening screw of coolant pump housing (arrow).
10 Unscrew vent line on coolant pump housing (arrow).
11. Unscrew coolant pump housing and remove together with coolant pump.
Installation
12 Install coolant pump housing with new gasket and tighten fastening screws to 27—33 Nm.
13 For further installation proceed vice versa to removal.
14 Add coolant (20—010).
15 Pressure-test cooling system with tester (approx. 1 bar gage pressure).