Reconditioning of coolant pump
WIS 20-220
Self-made tools
: : Spacing plate ejb b=2mm : iiee> Senor
= — 80
Pressing-in sleeve
1 Fan hub 7 O-ring 2 Coolant pump shaft with 8 Impeller compact bearing a 22.8–23.2 mm 3 Bearing housing b 2mm 5 Slide ring seal c Vent holes 6 Counterring
Disassembly
1 Support bearing housing with pertinent tubing and press out coolant pump shaft by means of a mandrel.
2 Knock sliding ring seal out of bearing housing.
3 Remove counterring from impeller.
Note: Always replace compact bearing and fan hub following disassembly.
4 Press in new compact bearing flush with bearing housing by means of a tube positioned against outer race.
Do not press against coolant pump shaft.
5 Coat mounting bore of sliding ring seal in bearing housing slightly with sealing compound (part No. 001 989 25 20).
Press-in or knock-in sliding ring seal with pressing-in sleeve.
Attention! Support only against bearing housing and not against coolant pump shaft.
6 Coat O-ring on counterring with brake cylinder paste and push with chamfered side (arrow) into thoroughly cleaned impeller.
10863
7 Clean sealing surfaces of counterring and sliding ring seal free of dust by means of a chamois cloth.
8 Degrease both shaft stubs and impeller in bore.
9 Press-on impeller flush with shaft while supporting coolant pump shaft.
10 Heat fan hub ona hot plate to approx. 300 °c (annealing color dark — up to light blue).
Place heated fan hub on a recessed base. Hold spacing plate on coolant pump shaft, slip coolant pump shaft on fan hub and apply a blast of compressed air against hub. Wait for a few seconds until fan hub is firm and then cool immediately in water bath.