Checking of expansion tank closing cover

WIS 20-430

Expansion tank closing cover

Checking of expansion tank closing cover – rysunek

new closing cover 0.15 Pressure relief 1.07 977° bar gage pressure valve opens at used closing cover 1.0–0.2 bar gage pressure

Vacuum valve starts opening at 0.1 bar vacuum

Special tools

&

Tester for cooling system – 001 589 48 21 00

Checking of expansion tank closing cover – rysunek

Double connection for expansion tank oy : . closing cover for cooling system tester 4 – 000 589 73 63 00

Checking pressure relief valve

1 Attach double connection on tester for cooling system by means of holders.

2 Place expansion tank closing cover on double connection.

3 Check by pumping opening pressure.

Checking vacuum valve

Checking of expansion tank closing cover – rysunek

The vacuum valve (arrow) should rest against rubber seal, valve should lift easily and snap back upon release.