Checking of expansion tank closing cover
WIS 20-430
Expansion tank closing cover
new closing cover 0.15 Pressure relief 1.07 977° bar gage pressure valve opens at used closing cover 1.0–0.2 bar gage pressure
Vacuum valve starts opening at 0.1 bar vacuum
Special tools
&
Tester for cooling system – 001 589 48 21 00
Double connection for expansion tank oy : . closing cover for cooling system tester 4 – 000 589 73 63 00
Checking pressure relief valve
1 Attach double connection on tester for cooling system by means of holders.
2 Place expansion tank closing cover on double connection.
3 Check by pumping opening pressure.
Checking vacuum valve
The vacuum valve (arrow) should rest against rubber seal, valve should lift easily and snap back upon release.