Removal and installation of engine longitudinal regulating shaft
WIS 30-310
1 Disconnect regulating linkage (5).
2 Push off locking eye (arrow), push longitudinal regulating shaft to the rear and remove.
Installation
3 For installation proceed vice versa. Grease bearing points as well as ball sockets of regulation with Molykote-Longterm 2.
4 Adjust regulating linkage (30-300).