Trouble-shooting
WIS 14-100
Very poor engine performance, black or blue smoke, tendency for knocking at full For complaints such as: load, poor starting characteristics with smoke, rough idie.
Throttle linkage correctly adjusted, connect revolution counter, engine at operating Test conditions: temperature, run engine at idle (750 + 50 rpm) (without increasing speed), steering in straight-ahead position, air conditioning switched off, selector lever for automatic transmission in position ‘‘P’’.
Exhaust gas recycling. Test:
Special tools
Tester O—1000 mbar for vacuum – 116 589 25 21 00
Clip – 000 589 40 37 00
Conventional tools
Rev counter
Shop-made measuring connection
117 078 01 45 Distributor
a Vacuum pipe 4x 1x 40mm
Test line 4 x 1 x 400 mm (for model year 1981 only)
14.4-100/1 USA F2
Functional diagram of vacuum pipe routing
bk
1 Intake pipe 65 Vacuum modulating valve Color coding:
31 Exhaust manifold 66 Injection pump bk = black
36 Thermo-valve 17 °C 67 Vacuum pump br = brown
60 EGR vaive 68 Bell crank with cam gr = green
61 Bellows a Automatic transmission pu = purple
62 Orifice b Air admission to passenger re = red
63 Orifice compartment wh= white
64 Switch-over valve c Brake booster
14.4-100/2 USA F2
14.4–100/3 USA F2
Disconnect white/brown vacuum pipe from distributor (arrow) and check for continuity. Failing this, renew thermovalve,
When the thermo-valve is allowed to cool down it should not be open at temperatures below 7 °C.
Checking switch-over valve (64)
Insert vacuum pressure gauge between switch-over valve and distributor. Vacuum reading about 700–800 mbar.
Checking for leakage
Disconnect distributor. Vacuum reading must be stable for about 2 minutes.
Renew switch-over valve if vacuum begins to drop.
Vacuum is stable:
Checking switch-over
For this purpose detach clip and disconnect vacuum pipe (arrow, black/red) from switch-over valve. Adjust control linkage until free movement ‘’L“’ is bridged at free movement rod. Vacuum must drop appreciably.
Checking EGR valve (60)
Renew EGR valve if it still fails to open and close.
= a
14.4-100/4 USA F2
Checking vacuum control
Connect vacuum tester to vacuum pipe (arrow, white/purple/brown) between thermo-valve (36) and EGR valve. Move control linkage and elevate idling speed to 1000 + 10 rpm (do not pull stop lever).
Vacuum must drop Vacuum fails to drop. to 340-390 mbar.
ar”
Checking orifice (63)
Check orifice for continuity, blowing out if necessary.
Exchanging orifice (63)
If vacuum still fails to reach 340–390 mbar or drops below this figure, it will be necessary to fit the next larger orifice for an excessive vacuum, and the next smaller one for inadequate vacuum.
Vacuum modulating valve (65) will have to be renewed if installation of a new orifice fails to produce the correct reading.
End of check
14.4-100/5 USA F2
Operational diagram, vacuum line layout
Intake manifold Vacuum control valve Color code 65 1 31 Exhaust manifold 66 Injection pump bk = black Thermo-valve 17 °C/63 °F 36 67 Vacuum pump br = brown 60 EGR valve 68 Reverse-transfer lever with cam gr green 61 Corrugated tube 69 Valve plate pu = purple 62 Orifice Central plug re =red 71 63 Orifice 72 Damper, vacuum wh = white 64 Switchover valve, automatic transmission Vent to passenger compartment 64a Switchover valve, idle shutoff — EGR Automatic transmission 64b Switchover valve, full throttle shutoff — EGR Brake unit c
Checkup
Note: At begin of test, yellow orifice (63) should be installed.
14.4-100/6 USA F2
14.4-100/7 USA F2
Pull central plug (71) from valve plate (69). Connect test line between tapping point (black orifice, arrow) on vacuum line for brake unit and valve plate connection (1). Close connection (2). Connect vacuum tester to connection (3).
Vacuum readout at switchover: Idle speed (throttle linkage at idle speed stop) ‘‘O’’ mbar. Bridge idle speed path (do not pull on stop lever) approx. 700–800 mbar.
Leak test: Let throttle linkage return to idle speed stop.
Vacuum should remain constant for approx. 2 minutes. Pull closing cap from connection (2).
Vacuum should drop to '’0”. If test values are not attained: Replace switchover valve (64a).
Check switchover valve (64b)
Pull central plug (71) from valve plate (69). Connect test line between tapping point (black orifice, arrow) on vacuum line brake unit and valve plate connection (2). Close connection (1). Connect vacuum tester to connection (3).
Vacuum readout: Idle speed (throttle linkage against idle speed stop) approx. 700–800 mbar.
Leak test: Disconnect tapping point for test line (arrow). Stop engine, vacuum should remain constant for approx. 2 minutes.
14.4-100/8 USA F2
Remove closing cap from connection (1). Throttle linkage at full stop, vacuum remains constant.
Let throttle linkage return to idle speed stop and pull off test line.
Vacuum should drop to ‘0’.
If test values are not attained, renew switchover valve (64b).
Checking EGR valve (60)
Start engine. Operate switchover valve (64a) by bridging idle path ’’L” on idle path rod. Pull off vacuum line on EGR valve (arrow) and plug-on again.
EGR valve should EGR valve not audibly close. closing.
a
Replace EGR valve (60).
er i
14.4-100/9 USA F2
Checking vacuum control
Connect vacuum tester between EGR valve (60) and straight connection of thermo-valve (36). Increase idle speed to 1000 + 10/min (do not pull on stop lever).
Vacuum readout Vacuum is exceeded 390–460 mbar. or not attained.
Check orifice (63)
Check if orifice is open and blow through, if required.
Change orifice (63)
If the vacuum is not attained, or is exceeded, install the next-larger size orifice if the vacuum is too high, and the next-smaller size orifice if the vacuum is too low.
If the correct vacuum is not attained by installation of another orifice, replace vacuum control valve (65).
End of test
14.4-100/10 USA F2