Removal and installation of immersion tube transmitter
WIS 47-710
A. Model 115.1
Tightening torques Nm
(mmersion tube transmitter 3.5–4
Removal
1 Take mat out of trunk and remove closing cover from floor of trunk.
2 Pull off coupler (1) on immersion tube transmitter (2).
3 Unscrew fastening nuts and pull out immersion tube transmitter.
4 Remove gasket from fuel tank and make sure that no sealing residue will drop inside tank.
Installation
| 5 For installation proceed vice versa as follows: | nN proceed vice versa as follows: Tee |
| a) Use new gasket. | t. || BARRE |
| b) Remove locking pin (arrow) prior to installing | 1g pin (arrow) prior to installing 5 coe ee 2 |
immersion tube transmitter.
c) Plug-on coupler and check fuel readout for function.
d) Tighten nuts crosswise to 3.5–4 Nm.
e) Plug-on coupler for fuel readout.
f) Check for leaks.
Tightening torque
Nm
35–43 Immersion tube indicator
Removal
1 Remove first aid kit and storage tray (arrow).
2 Pull off coupler (66) for fuel readout on immersion tube transmitter (65) and secure against slipping off by means of wire.
3 Unscrew immersion tube transmitter.
Installation
4 For installation proceed vice versa, paying attention to the following instructions:
a) Use new rubber sealing ring.
b) Prior to inserting immersion tube transmitter, remove locking pin (arrow).
c) Plug-on coupler and check fuel readout for function.
d) Install immersion tube transmitter and tighten to 35–43 Nm.
e) Plug-on coupler for fuel readout.
f) Check for leaks.
C. Model 123.1 T-sedans and special vehicles with body made by others
Removal
1 Loosen luggage compartment floor by turning tommy lock and remove .
2 Remove storage compartment.
immersion tube transmitter (65).
Installation
4 For installation proceed vice versa, proceed as follows:
a) Unse new rubber sealing ring.
V7-WHO
b) Remove locking pin (arrow) prior to installing immersion tube transmitter.
c) Plug-on coupler and check operation of fuel readout.
d) Tighten immersion tube transmitter to 35–45 Nm.
e) Plug-on coupler for fuel readout.
f) Check for leaks.
07 -WPG2