Inspection and adjustment of no-load max speed

WIS 07.1-105

Test values

Inspection and adjustment of no-load max speed – rysunek

. Max speed no-load

Model E

oae ngine (end of governed speed) 1/min

615, 616 5200-5400 115.1 — 617 4700–5200

615, 616 4800–5200

123.1 616, 617 4700–5200

615, 616, 4900-5200

Special tools

Oil telethermometer – 116 589 27 21 00

Adaptor for revolution counter votre – 616 589 00 63 00

Conventional tool

Revolution counter, mechanical with hexagonal adaptor e.g. made by Gann, D-7000 Stuttgart 1

Testing i) Ls

1 Connect revolution counter. == Use adaptor when connecting mechanical revolution (= counter.

iY 1074-8543

3 Slowly accelerate with accelerator pedal and read revolution counter. Specified engine speed should be attained.

Adjustment (M-injection pump with pneumatic

Inspection and adjustment of no-load max speed – rysunek

governor)

4 Adjust speed by means of full load stop screw (1) on throttle unit.

Screwing in = speed decrease

Screwing out = speed increase

Full load stop screw n= Regulating lever a = Adjustment max 2mm

Adjustment (a’’) of throttle valve should not exceed max 2 mm.

If the full load stop screw is screwed in still further, the air feed will be throttled and driving performance will drop.

If the throttle unit can no longer be adjusted, tension or slacken governor spring by means of compensating washers (07.1–130).

5 If the respective speed is not attained on MW and M/RSFinjection pumps, check for presence of vacuum at vacuum box on injection pump. For this purpose, pull off hose on vacuum box. If the speed is still not attained, remove injection pump and adjust maximum speed free of load on a Bosch injection pump test bench.