Viscofan coupling, temperature—controlled (engine 617)

WIS 20-310

Operation

Viscofan coupling, temperature—controlled (engine 617) – rysunek

The Viscofan coupling is a maintenance-free, hydraulic coupling which operates independent of temperature as well as infinitely variable.

When the engine is started (cold start), the fan will initially run at higher speed until the oil has flown back from the working chamber (75) into the reservoir (74) (approx. 1–3 minutes). The fan coupling will then switch off. The fan speed in disconnected condition depends on engine speed, but a fan speed of approx. 2100/min should not be exceeded.

This condition remains in force as long as the engine maintains its normal operating temperature.

Viscofan coupling, temperature—controlled (engine 617) – rysunek

\f the coolant temperature increases as the result ofa higher load or higher outside temperatures, the air which flows through the radiator and actuates bimetallic strip will become warmer. The bimetallic strip (69) changes its shape under the increasing heat and opens at approx. 73°C a valve by means of a control pin (68) and thereby the path of the oil from the reservoir (74) into the working chamber (75) so that the fan will be additionally engaged.

During this control operation, the coolant temperature is between 90 and 95°C.

With the clutch engaged, the fan speed in lower speed range will increase approximately proportional with the increasing engine speed, but will not exceed 3500/ min in upper speed range.

Checking connected temperature

60 Coupling body (secondary member) Run engine at 4000–4500/min. When a coolant tem61 Pulley (primary member) perature of 90 to 95°C is attained, the fan speed 62 Flange shaft 63 Sealing ring should increase by approx. 1000/min., which can be 64 Needle bearing 65 Cooling fins clearly noticed accoustically. 66 Oil scraper 67 Compression spring 68 Control pin 69 Bimetallic strip

Reconditioning

70 Cover with holding clip 71 Intermediate washer 72 Feed hole 73 Valve lever A defective coupling cannot be repaired with work74 Reservoir shop equipment, and a new coupling should be instal75 Work chamber led.

Temperature-controlled Viscofan couplings should be transported and stored vertically. For short periods— e.g. during assembly — the coupling may rest on a flange, but never on front end.