Checking radiator cap
WIS 20-430
Radiator cap
| Pressure relief valve opens at | new radiator cap 5 1.0 + 0 bar gauge pressure used radiator cap 1.0 — 0.2 bar gauge pressure | |
| Radiator valve opens starting at | 0.1 bar vacuum | (RE Nee Pee 6 |
Special tools
= Tester for cooling system and radiator cap (a on – 001 589 48 21 00
Ee Double connection for radiator cap e 2” 11004-8326 – 000 589 73 63 00
Checking pressure relief valve
1 Attach double connection to leak tester by means of holding clips.
2 Place expansion tank cap on double connection.
3 Test opening pressure by pumping.
Checking vacuum valve
The vacuum valve (arrow) should rest against rubber seal, should be easily lifted and snap back upon release.