Balancing balance plate statically
WIS 03-344
Special tool Mounting drift for balance plate – 617 589 02 63 00
Commercially available tool
Roller type EO e.g. Trebel, 4030 Ratingen
Note The balance of old balance plates must be transferred to new ones.
A fractured balance plate must be cemented, if possible, together with all parts and balanced statically with the new one.
Static balancing
1 Position new balance plate on balancing drift, set off from old one by 180°.
2. Allow balancing drift with two balance plates to settle down on roller.
3 Spot-drill new balance plate until balance plates stop on roller at any position without swinging backward or forward:
Note positions of balancing holes (patterns).
Drilling pattern 1
Holes max. 25 mm deep
Drilling pattern 2
Holes max. 20 mm deep
Engine 617
Holes max. 20 mm deep