Testing preglow system
WIS 15-4000
Operation no. of operation texts and work units or standard texts and flat rates: 154.000
P15-5247–57
Aleté Preglow indicator lamp B11/8 Coolant temperature sensor, afterglow N14 Praglow time relay Re Glow plugs
Test in accordance with test program „preglow system” 0… ee ee eee perform.
Fluke 23 DB, 83, 88 ITT Metrix MX 47, 50, 51, 52
gtime RA 15.1621-4000/1
Note
Circuit protection of preglow circuit The preglow time relay is operational again once An electronic short circuit protection is installed the short circuit has been rectified and the in the pregiow time relay. In the event of a short ignition key turned back to position ”0”. circuit in the glow plugs or in the wiring, the circuit is interrupted.
Designation of the two preglow time relay couplings Couplings with the pins T, 31, 50, 15, LA: (1.1) to (1.5).
Coupling with the pins G1—G6: (2.1) to (2.6)
Wiring diagrarns of preglow system see Wiring Diagram Volume Model 124 as of 10/92 Volume 1.
P15-524.8–13
Troubleshooting table of preglow system
eoahge AA 15.1621-4000/2
Current clamp over glow plug lead
N14 Preglow time relay Coupling at preglow time relay N14x1
ohne §=RA 15.1621—~4000/3
egies. RA 15.1621-4000/4