Retrofitting Charge Pressure Shut-off Relay
WIS 30-0405
Preceding work: Operation no. of operation texts and work units or standard texts and flat rates:
A. Scope of work Model 124 B. Scope of work Model 201 C. Cable harnesses and wiring diagrams D. Parts
1 Cable hamess $27 AIC compressor/charge pressure shut-off K12/1 Relay, cruise control/charge air cutoff microswitch $e7r7 Microswitch, charge pressure shut-off
«uti §=RA 30.0405-0405/1
A relay can be retrofitted to prevent part throttle jerking with Tempomat. The following parts are to be checked before installation: ® Control Linkage 30-300 ® Cable harness connector of microswitch Detach charge pressure shut-off (S27 or $27/7) and perform a test drive (with Tempomat operating). If the part throttle jerking is eliminated by this, a relay circuit, which renders the charge pressure shut-off inoperative during Tempomat operation, must be installed.
A. Scope of work Model 124
1 Produce cable harness according to Section C.
2 Disconnect ground cable at battery.
3 Remove fuse and relay box cover.
4 Detach fuse carrier and clip out relay bracket.
5 Pull ends of cable harness with the 4 jacks through the rubber grommet on the right side in the fuse and relay box. Then fit 6-pin connector on cable hamess (assignment refer to Section Relay, cruise control/charge air cutoff K12/1 C).
«phim §=—RA 30.0405-~-0405/2
6 Clip 6-pin connector into the relay holder of the fuse and relay box (Field E).
7 Assemble relay holder and install relay.
8 Fit fuse and relay box cover. y
9 Route cable harness on the left wheelhouse for plug connection of Ternpomat actuator.
10 Install 8-pin adapter plug of the cable harness between the plug connector of the Tempomat actuator.
1 Cable harness
11 Route ground cable to the ground point (W3) and screw on.
1 Cable hamess
2 Bott M6 x 16
3 Washer A 6.4 W3 = Ground, left front wheelhouse (at ignition coil)
12 Route cable with jack on actuator cable harness along to switch (S27 or $27/7) on vehicles with refrigerant compressor and fasten.
oon Location of switch $27 or $27/7 on Engine 602 1 Cable harness
ptthips = =RA 30.0405-0405/3
take ground cable (assignment 29) out of the connector for the switch (S27/7), pinch off jack and tie back cable. Then insert the ground cable in assignment 2 of the new cable harness.
14 On vehicles with refrigerant compressor, remove ground bridge in the connector for switch (S27), insert remaining ground cable in assignment 5. Then insert the ground cable in assignment 4 of the new cable harness.
15 Connect ground cable to battery.
Location of switches (S27 or $27/7) on Engine 603
16 Carry out test drive. 1 Cable hamess
B. Scope of work Model 201
1 Produce cable harness according to Section C.
2 Disconnect ground cable from battery.
3 Remove cover from supplementary relay and fuse box and detach relay holder.
4 Clip in 12-pin connector of cable harness in the relay holder and fasten relay holder.
5 Press relay on the 12-pin connector and reassemble cover to the supplementary relay and fuse box. Cable hamess K12/1 Relay, cruise control/charge air cutoff
ptthim = RA 30.0405-0405/4
6 Route cable harness to the ground point (W3) on left wheelhouse.
7 Screw ground cable onto the ground point (W3).
1 Cable harness Bolt M6 x 16 Washer A 6.4
4 Nut M6 W3 Ground, left front wheelhouse (at ignition coil)
8 Route cable harness further to the plug connector of the Tempomat actuator and assemble 8-pin adapter plug between the plug connector of Tempomat actuator.
1 Cable hamess
9 Route cable with jack on the actuator cable harness along to the switch (S27 or $27/7) on vehicles with refrigerant compressor and fasten.
10 On vehicles without refrigerant compressor, take ground cable (assignment 2) out of the connector for the switch (S27/7), pinch off jac and tie back cable. Then insert the ground cable in assignment 2.
Lacation of switch (S27 or $27/7) 1 Cable hamess
«pith = =RA 30.0405-0405/5 remove ground bridge in the connector for switch (S27), insert remaining ground cable in assignment 5. Then insert the ground cable in assignment 4 of the new cable harness.
Connect ground cable to battery. 12
13 Carry out test drive.
C. Cable harnesses and wiring diagrams
Cable hamess of Model 124
oii §~=RA 30.0405-0405/6
Note
Only assemble 6-pin connector once the cable harness is routed into the relay and fuse box. In addition, the loose plug jacks are to be inserted in assignments 1 to 5 on the 8-pin adapter plug.
Cable harness for Model 201
Note The loose plug jacks are to be inserted in assignments 1 to 5 on the 8-pin adapter plug.
«uty §~=RA 30.0405-0405/7
Wiring diagram Model 124 (vehicles without refrigerant compressor)
K12/1 Relay, cruise control/ charge air cutoff M16 = Cruise control actuator $27/7 Microswitch charge pressure shut-off Ww3 Ground, lett front wheelhouse (at ignition coil)
Wiring diagram Model 124 (vehicles with refrigerant compressor)
K12/1 Relay, cruise control/ charge air cutoff M16 = Gruise control actuator $27 Microswitch compressor shut-off/ charge pressure: shut-off Ww3 Ground, left front wheelhouse (at ignition coil)
«oti» ~=RA 30.0405-0405/8
Wiring diagram Model 201 (vehicles without refrigerant compressor)
K12/1 Relay, cruise control/ charge a M16 = Cruise control actuator $2777 Microswitch charge pressure shut-off w3 Ground, left front wheelhouse (at ignition coil)
Wirlng diagram Model 201 (vehicles with refrigerant ompressor)
K12/1 Relay, cruise control/ charge air cutoff M16 = Cruise control actuator $27 Microswitch compressor shut-oft/ charge pressure shut-off Ww3 Ground, left front wheelhouse (at ignition coil)
gti §=RA 30.0405-0405/9
D. Parts
oii» §~=RA 30.0405-0405/10