AR20.30-P-4300HA Testing cooling system cap |2.4.93

WIS 20-4300ha

AR20.30-P-4300HATesting cooling system cap|2.4.93
ENGINE 111, 120, 601, 602, 603, 604, 605, 606 /7
AR20.30-P-4300HA Testing cooling system cap |2.4.93 – rysunek
AR20.30-P-4300HA Testing cooling system cap |2.4.93 – rysunek

A Testing cap with detent B Testing 2-stage cap

B

P20.30-0223–06

3) 3] Removing, installing [i] The cooling system cap in model 163 cannot be tested; it should be replaced if necessary

1 Open cooling system cap (5, 5a} i) Cap (5, 5a)

Cap with detent: carefully turn cap to the first detent, release pressure, and then unscrew cap.

2-stage cap: turn cap half a turn anticlockwise, release pressure, and then unscrew cap. fq) Testing cooling system cap with detent 2.1 Inspect cap (5) for corrosion ® Replace if corrosion present 3.1 Attach test cap (3) and double union (4) to Tester (2) 124 589 24 2100 tester (2) [Fl test cap (3) 124 589 009100 Double union (4) – 000 589 77 63 00

41 Screw cap (5) with detent onto double union (4)

AR20.30-P-4300HA Testing cooling system cap |2.4.93 – rysunek

Test pressure relief valve Determine opening pressure of the cap (5) BE20.30-P-1001-01A by pumping; replace cap (5) if necessary. As of 02/1986 the opening pressure of the cap has been increased from the previous 1.2 bar to 1.4 bar; consequently, the permissible coolant temperature is increased from 125 to 129 °C with standard antifreeze protection down to — 30°C.

Test vacuum valve (6) If cap (5) fitted: the vacuum valve (6) BE20.30-P-1003-01A should be resting against the rubber seal (arrow), it can be raised easily and springs back when released.

Testing 2-stage cap

Attach test cap (3a) to tester (2) Tester (2) 124 589 24 2100 (F] Test cap (3a) 210 58900 9100 Screw on 2-stage cap (5a) at test cap (3a) Test pressure relief valve Determine opening pressure of the cap (5a) BE20.30-P-1004-01A by pumping; replace cap (5a) if necessary. Function see

Function of 2-stage cooling system cap GF20.30-P-1000A

Install in the reverse order

Radiator or expansion reservoir cap Number Designation a Cap 2-stage cap

8E20.30-P-1001-01A Cap code number 140 140/200 BE20.30-P-1002-01A Pressure relief valve opens new bar gage 1.4+0.1 – used bar gage 1.4–0.1 – BE20.30-P-1003-01A Vacuum valve opens {reference bar vacuum 0.1 0.1 value) BE20.30-P-1004-01A Pressure relief valve opens Ist stage bar gage – 1.4641

coolanttemp. – >= 130/134

2ndstage bar gage – 2.041

coolant temp. – > 137/143

AR20.30-P-4300HA Testing cooling system cap |2.4.93 – rysunek
AR20.30-P-4300HA Testing cooling system cap |2.4.93 – rysunek
AR20.30-P-4300HA Testing cooling system cap |2.4.93 – rysunek

BE20.30-P-1005-01A Test pressure for pressure-testing the bar gage 1.4 1.4 cooling system

——12asago09100 «JX s2tt0589009100 =f \ 210589036300 Tester Test cap Test cap Adapter

AR20.30-P-4300HA Testing cooling system cap |2.4.93 – rysunek

\ 000589776300 _/ Adapter