Testing Fuel Pump for Delivery
WIS 07.1-5701
Preceding work: Operation no. of operation texts and work units or standard texts and flat rates: 07-5701
Testers (001, 021) 2… eee eee eee ee wee connect. Return line (81) 2… ee ee ee eee disconnect and hold in measuring beaker (approx. 1 1).
Note The return line to the fuel tank must be sealed. Glow start switch 2.6… 2. cece eee eee eee move into position „0”, the injection pump is in the zero delivery position.
apt = RA 07.1.1051-8701/1
Contact handle (040) «1… …….000.. ++. connect to terminal 30 and terminal 50 and start engine for 30 seconds. Use stopwatch (041). Specification: Delivery at least 150 cm*/30 seconds at 150 rpm. If the specification is not achieved, test fuel pressure (07.1-5702).
opti = RA 07.1.1051~5701/2
Testing
1 Connect digital tester (001) as shown in connection diagram.
001 Digital tester 021 TDC pulse generator
2 Disconnect return line (E) and hold in measuring beaker.
3 Turn glow start switch into position ”0”, the injection pump is in the „zero” delivery position when performing this step.
agin = RA 07.1.1051-5701/3
4 On model 124 and model 201, unplug coupling (X27) and connect adapter cable to terminal 50.
Model 124
Model 201
Model 126
5 Connect contact handle to adapter cable or to terminal 50 (KI 50) and to terminal 30 (KI 30) and start engine for 30 seconds. Use stopwatch. (Starting voltage at least 10 V)
Delivery: at least 150 cm*/30 seconds at 150 rpm.
If the specification is not achieved, test fuel pressure (07.1-5702).
auiiiyn = RA 07.1.1051-5701/4