Checking oxygen sensor failure indicator

WIS 14-116

Checking oxygen sensor failure indicator – rysunek
Checking oxygen sensor failure indicator – rysunek

Al Instrument cluster N3 Control unit CIS-E injection system a To control unit C!IS-E injection system (N3) A1e10 Indicator lamp oxygen sensor K1/1 Relay overvoltage protection jack 1

Test condition

© Battery voltage 11-14 V

Electrical wiring diagrams (07.3-128).

Explanation of symbols

(=H) Multimeter Ground — Jack Multimeter measuring mode resistance _— Plug Multimeter measuring mode DC voltage

Actuation’ RequirementSet value/ Functioncause/Remedy
Ignition: ON Engine: Start — sensorOxygen failure indicator (A1e10) lights up briefly.lamp defective. sensor failure (A1e10) without circuit (A1e10) — (N3)
Ignition: ON Engine: StartOxygen sensor failure indicator (A1e10) lights up briefly.indicator lamp, renew if required.
Ignition: ON Wiring pulled off11-14Vcircuit ) — (K1/1) circuit (K1/1) — (N3) (a).
Ignition: OFF Wiring pulled off12circuit.
Checking oxygen sensor failure indicator – rysunek
Checking oxygen sensor failure indicator – rysunek
Impulse period display _ testTest step’ Scope ofActuation/ RequirementSet value’ FunctionPossible cause’Remedy
–3.2 WiringIgnition: OFF Wiring pulled off<12Open circuit.
–4.0 WiringIgnition: OFF Wiring pulled off<12Open circuit.
Checking oxygen sensor failure indicator – rysunek

Special tool

Checking oxygen sensor failure indicator – rysunek

Commercially available tester

Checking oxygen sensor failure indicator – rysunek

Multimeter

Note Failure of the oxygen sensor is indicated in the instrument cluster (A1) by a lit indicator lamp “oxygen sensor” (A1e10). The lamp is activated by the control unit CIS-E injection. The indicator lamp lights up briefly when the ignition is switched on.