Checking oxygen sensor failure indicator
WIS 14-116
Al Instrument cluster N3 Control unit CIS-E injection system a To control unit C!IS-E injection system (N3) A1e10 Indicator lamp oxygen sensor K1/1 Relay overvoltage protection jack 1
Test condition
© Battery voltage 11-14 V
Electrical wiring diagrams (07.3-128).
Explanation of symbols
(=H) Multimeter Ground — Jack Multimeter measuring mode resistance _— Plug Multimeter measuring mode DC voltage
| Actuation’ Requirement | Set value/ Function | cause/Remedy |
| Ignition: ON Engine: Start — sensor | Oxygen failure indicator (A1e10) lights up briefly. | lamp defective. sensor failure (A1e10) without circuit (A1e10) — (N3) |
| Ignition: ON Engine: Start | Oxygen sensor failure indicator (A1e10) lights up briefly. | indicator lamp, renew if required. |
| Ignition: ON Wiring pulled off | 11-14V | circuit ) — (K1/1) circuit (K1/1) — (N3) (a). |
| Ignition: OFF Wiring pulled off | 12 | circuit. |
| Impulse period display _ test | Test step’ Scope of | Actuation/ Requirement | Set value’ Function | Possible cause’Remedy | |
| – | 3.2 Wiring | Ignition: OFF Wiring pulled off | <12 | Open circuit. | |
| – | 4.0 Wiring | Ignition: OFF Wiring pulled off | <12 | Open circuit. |
Special tool
Commercially available tester
Multimeter
Note Failure of the oxygen sensor is indicated in the instrument cluster (A1) by a lit indicator lamp “oxygen sensor” (A1e10). The lamp is activated by the control unit CIS-E injection. The indicator lamp lights up briefly when the ignition is switched on.