Checking exhaust gas recirculation (EGR)

WIS 14-475

Checking exhaust gas recirculation (EGR) – rysunek
Checking exhaust gas recirculation (EGR) – rysunek

A. Exhaust gas recirculation with vacuum control valve model year 1986/87

Checking exhaust gas recirculation (EGR) – rysunek
Set value/ Functioncause/Remedy
–
applyswitches audiblyEGR valve
applyIrregular engine operationEGR valve
Checking exhaust gas recirculation (EGR) – rysunek
Checking exhaust gas recirculation (EGR) – rysunek
Checking exhaust gas recirculation (EGR) – rysunek

Coolant thermovalve. temperature > 50°C open. < 50°C closed.

Coolant thermovalve. temperature vacuum. > 50 °C vacuum remains.

atapprox.mbar are
1500 rpmat 1500 rpm,
< 100 mbarline assignment
_increaseapprox.assembly
3200 rpmFig.). If set values
400 mbarobtained, renew
control valve.

Mixture control unit O2-sensor indicator lamp A1e10 Diaphragm pressure controller 40 A1p8 Electronic speedometer Fuel filter 55 Air flow sensor position indicator Fuel reservoir B11/2 Coolant temperature sensor (EZL/CIS-E) 57 Fuel cooler B18 Altitude correction capsule 74 Fuel tank G3/2 Heated O2-sensor 75 Crankshaft position sensor 76 Vent valve L5 Charcoal canister M3 Fuel pump 77 Purge valve 78 N1/2 Electronic ignition control unit (EZL) 50 °C thermovalve N3 CIS-E control unit 79 Exhaust gas recirculation valve N8 89 Idle speed control unit Control valve N16/4 Fuel pump relay with kickdown cut-out 90 Injection valve R17/1 Reference resistor (CIS-E) 92 $29/2 Air pump Full load/idle speed detection throttle valve switch 125 126 Air shutoff valve 11 Ignition coil Check valve (injected air) Y1 Electrohydraulic actuator 127 A/C compressor electromagnetic coupling Firewall catalytic converter YS/1 157 Underfloor catalytic converter Y6 Idle speed air valve 158 Starting valve Y8 Y32 Air pump switchover valve Y33 Air pump electromagnetic coupling

Checking exhaust gas recirculation (EGR) – rysunek

WS/VID.

Function diagram air injection and exhaust gas recirculation up to 08/87

N12 Control unit ignition system (EZL) 79 Thermovalve Y32 Change-over valve air pump 89 Exhaust gas recirculating valve Control valve a from air cleaner 90 Throttle assembly b to fuel tank 123 c Ventilation 125 Air pump Air shut-off valve

1 Mixture control unit 126 Check valve (injection air)

40 Diaphragm pressure regulator 127 Check valve (vacuum)

77 Charcoal canister 128 Timing case cover

78 Purge valve 129

B. Exhaust gas recirculation without vacuum control valve as of model year

1988

Note

Checking exhaust gas recirculation (EGR) – rysunek

The control valve in the vacuum line between throttle assembly and exhaust gas recirculation valve is no longer required as of 09/87. The exhaust gas recirculation valve is connected with vacuum directly only as a function of the thermovalve.

Checking exhaust gas recirculation (EGR) – rysunek

wsivi br

P14-0018-55A

Impulse period displayTest step/ Scope of testMeasuring device/ Test connectionActuation/ RequirementSet value/ FunctionPossible cause/Remedy
–1 Vacuum line ws/vibron EGR valve (60)
–Vacuum tester (019)on EGR valve (60)connect, apply 300 mbar vacuum.switches audiblyRenew EGR valve
–3 Engine at idle speedon EGR valve (60)connect, apply 300 mbar vacuum.Irregular engine operationRenew EGR valve
–4 Check function of thermovalve (79)Pull off both vacuum lines. Connect vacuum tester to inclined connection.Connect vacuum,Coolant temperature > 50°C open. < 50°C closed.Renew thermovaive.
–5 Check thermovalve (79) for leaksConnect vacuum tester to inclined connection.Plug straight connection. Apply vacuum.Coolant temperature > 50°C vacuum remains.Renew thermovalve.