Checking injection valves

WIS 07.3-135

Test data

Injection valves Bosch no. 0 437 502 010

with new injection valves 3.5–4.1 bar gauge pressure Opening pressure with used injection valves min. 3.0 bar gauge pressure

Tightening torques Nm

Injection lines to fuel distributor (reference value)10–12
Injection lines to injection valves (reference value)10–15

Conventional tools

Bosch order designation Valve tester Bosch KD-JE 7452 KD-JE 7452 JE 74

Nozzle tester EFEP 60 H’) Bosch no. 0 684 200 700

Pressure gauge O—6 bar gauge pressure Bosch no. 1 687 231 00 Quality class 1.0 housing dia. = 100 mm

Pipe line Bosch no. 1 680 750 001

1) Corresponds to nozzle testers used up to now. To check injection valves, the pressure gauge named above or the pressure gauge of pressure measuring device 100 589 13 21 00 will be required.

Note

Checking injection valves – rysunek

The nozzle or valve tester serves to check the opening pressure, the buzzing test and the fuel jet, and also for checking the injection valves for leaks.

Prior to checking injection valves, fill container of tester and bleed. For testing, use kerosene only.

Checking injection valves – rysunek

Injection valves, beyond tolerance must be renewed. Injection valves can be individually interchanged within one set.

For checking, remove injection valves (07.3–215).

1 Coarse leak test:

a) Connect removed injection valves to tester. Bleed pressure line with shutoff valve open and coupling nut released by actuating lever slowly several times. Then tighten coupling nut.

b) With shutoff valve open, slowly actuate hand lever (4 s/stroke) and build up pressure up to max. 1.5 bar gauge pressure. If injection valve shows a leak, replace.

2 Check opening pressure.

Close shutoff valve. Operate hand lever quickly several times to flush injection valve.

Open shutoff valve and check opening pressure while moving lever slowly.

3 Fine leak test:

Close shutoff valve. Operate hand lever fast several times to flush injection valve, open shutoff valve and increase pressure slowly up to 0.5 bar gauge pressure at previously determined opening pressure and hold. No drops should show up at injection valve within 15 seconds.

4 Buzzing test, evaluation of jet:

Close shutoff valve and flush valve by operating lever several times (0.5 s/stroke). Then reduce lever speed to approx. 1 s/stroke. Valve should then buzz. No drops should show up at valve mouth. There should be no cord-type jet. One-sided, atomized jet formations within a total spray angle of approx. 35° is permitted.

Checking injection valves – rysunek

Damaged injection valves

Checking injection valves – rysunek

Formation of drops

Checking injection valves – rysunek

Cord-type jet

Poorly proportioned jet

Checking injection valves – rysunek

Good injection valves

Well proportioned jet

Checking injection valves – rysunek

Mitts

Slightly one-sided atomization