Removal and installation of immersion tube transmitter (continued)
WIS 47-710a
| All models | |
| Tightening torque | Nm |
| Immersion tube transmitter | 35–43 |
Removal
1 On model 107.04, remove hard top, open top lock and unfold top.
2 Remove closing cap (3).
Model 107.04
3 On models 107.02 and 116, remove first aid kit and tray (arrow).
4 Pull coupler (1) from immersion tube transmitter (4) and protect against slipping by means of a wire.
5 Unscrew immersion tube transmitter.
Installation
6 For installation proceed vice versa, paying attention to the following items:
a) Use new rubber sealing ring.
b) Remove locking pin (arrow) prior to installation of immersion tube transmitter.
c) Check function on fuel gauge.
d) Tighten immersion tube transmitter to 35–43 Nm.
e) Plug-on coupler for fuel gauge.
f) Check for leaks,