Removal and installation of radiator (continued)

WIS 20-430

Removal and installation of radiator (continued) – rysunek

Cap

new cap 1.0 wore bar gauge pressure Pressure relief valve opens at used cap

1.0_ bar gauge pressure 0.2

Vacuum valve opens at 0.1 bar vacuum

Special tools

Tester for cooling system and radiator cap – 001 589 48 21 00

Removal and installation of radiator (continued) – rysunek

Double connection for expansion tank cap for tester CBB rooe-sore – 000 589 73 63 00

Checking pressure relief valve

1 Attach double connection to tester by means of holding clips.

2 Place expansion tank cap on double connection.

3 Check opening pressure by pumping.

Checking vacuum valve

Removal and installation of radiator (continued) – rysunek

The vacuum valve (arrow) should rest against rubber gasket, lifting-off should be easy. Valve should snap back when released.