Testing breakerless transistorized ignition system TSZ 4
WIS 15-562
Test values
| Battery rest potential | approx, 12 V | |
| Ignition coil voltage | terminal 1 and ground – terminal 15 and ground | approx. 0.5–2 V approx. 4.5 V |
| Input voltage series resistor | approx. 12 V | |
| coil resistor | primary terminal 1 and 15 | 0.33–0.46 2 |
| Ignition | — secondary terminal 1 and 4 | 7–12 kQ |
| Transmitter resistance between terminal 7 and 31d | 600 + 100 22 | |
| Transmitter coil with control line terminal 7 and ground | oo | |
| Dwell angle at | approx. 1500 rpm | 25–39° |
| : approx. 5000 rpm!) | 33–40° | |
| 1) Perform dwell angle test at 5000 rpm only if complaints refer to misfiring at high speeds. Conventional testers | ||
| Voltmeter, ohmmeter, dwell angle measuring instrument, revolution counter | SO |
Wiring diagram breakerless transistorized ignition with test values
1 Two-point cable connector a Ignition starting switch terminal 15 Color code
2 Switching unit b Instrument cluster, revolution counter br = brown
3 Series resistor 0.4 Q c Diagnosis socket ge = yellow
4 Series resistor 0,6 {2 d Terminal 16 starter gn = green
5 Ignition distributor with transmitter section = red
6 Ignition coil sw = black
Note Gefahrliche Hochspannung! Vorsicht bei Arbeiten an der Zundanlage In the event of complaints about misfiring, check high voltage side of ignition system first (spark plugs,
Danger! High voltage
ignition cable, spark plug connectors). Observe caution when working on the ignition system If complaints are about starting-up of engine, perform
Danger! Haute tension
the following tests on ignition system in addition to Attention lors de travaux au test at fuel side: systéme d’allumage _ 7
Visual ual checkup
Check electric screw connections and plug connections of ignition system for tight seat.
Voltage test
Note: With ignition switched on and engine stopped, a constant primary current of approx. 8 Amps. will flow in this ignition system.
1 Input voltage on series resistance 0.4 Q cable color black/red (15/54):
Nominal value approx. 12 Volts
2 Voltage on ignition coil at approx. 20 °C:
Terminal 15 and ground = approx. 4.5 Volts Terminal 1 and ground = 0.5–2.0 Volts
a) |f value is exceeded on terminal 1, switchgear is defective and should be replaced.
b) If value on terminal 1 is attained, but no ignition voltage (firing spark) is induced, check transmitter section in ignition distributor (5) and secondary winding of ignition coil.
Resistance values ignition coil:
Primary winding terminal 15 and terminal 1 = 0.33–0.46 2
Secondary winding terminal 1 and terminal 4 = 7–12 kQ
Checking dwell angle
Note: The dwell angle (timing angle) cannot be adjusted. The inspection serves to check function of switchgear (dwell angle control).
Connect dwell angle measuring instrument (Connection similar to Sl-standard switchgear).
Nominal value at
Engine speed Dwell angle
1500+50/min 25-—-39° 5000+50/min’) 33–40°
1) Check at 5000/min only if complaints are about misfiring at high speeds.
If this value is not attained when measuring dwell angle, check ignition distributor transmitter section first. If transmitter section is in order, exchange switchgear.
Testing ignition distributor transmitter section
Pull off control line of ignition distributor on switchgear and connect ohmmeter.
1 Test transmitter resistance between terminal 7 and 31d.
Nominal value: 600 + 100 Q
Note: On cold engine the ohmic value should be in Ohmmeter connection for testing transmitter resistance lower half of specified value, on warm engine in upper half.
my
2 Test transmitter coil including control line for ground connection.
Nominal value: terminal 7 and ground = °°
3 Check transmitter section for mechanical damage. There should be an air gap between rotor and stator.
Note: If transmitter section is defective, exchange 6432/1 complete ignition distributor.
Ohmmeter connection for testing ground connection