Testing breakerless transistorized ignition system TSZ 4

WIS 15-562

Test values

Battery rest potentialapprox, 12 V
Ignition coil voltageterminal 1 and ground – terminal 15 and groundapprox. 0.5–2 V approx. 4.5 V
Input voltage series resistorapprox. 12 V
coil resistorprimary terminal 1 and 150.33–0.46 2
Ignition— secondary terminal 1 and 47–12 kQ
Transmitter resistance between terminal 7 and 31d600 + 100 22
Transmitter coil with control line terminal 7 and groundoo
Dwell angle atapprox. 1500 rpm25–39°
: approx. 5000 rpm!)33–40°
1) Perform dwell angle test at 5000 rpm only if complaints refer to misfiring at high speeds. Conventional testers
Voltmeter, ohmmeter, dwell angle measuring instrument, revolution counterSO
Testing breakerless transistorized ignition system TSZ 4 – rysunek

Wiring diagram breakerless transistorized ignition with test values

1 Two-point cable connector a Ignition starting switch terminal 15 Color code

2 Switching unit b Instrument cluster, revolution counter br = brown

3 Series resistor 0.4 Q c Diagnosis socket ge = yellow

4 Series resistor 0,6 {2 d Terminal 16 starter gn = green

5 Ignition distributor with transmitter section = red

Testing breakerless transistorized ignition system TSZ 4 – rysunek

6 Ignition coil sw = black

Note Gefahrliche Hochspannung! Vorsicht bei Arbeiten an der Zundanlage In the event of complaints about misfiring, check high voltage side of ignition system first (spark plugs,

Danger! High voltage

ignition cable, spark plug connectors). Observe caution when working on the ignition system If complaints are about starting-up of engine, perform

Danger! Haute tension

the following tests on ignition system in addition to Attention lors de travaux au test at fuel side: systéme d’allumage _ 7

Visual ual checkup

Check electric screw connections and plug connections of ignition system for tight seat.

Voltage test

Note: With ignition switched on and engine stopped, a constant primary current of approx. 8 Amps. will flow in this ignition system.

1 Input voltage on series resistance 0.4 Q cable color black/red (15/54):

Nominal value approx. 12 Volts

2 Voltage on ignition coil at approx. 20 °C:

Terminal 15 and ground = approx. 4.5 Volts Terminal 1 and ground = 0.5–2.0 Volts

a) |f value is exceeded on terminal 1, switchgear is defective and should be replaced.

b) If value on terminal 1 is attained, but no ignition voltage (firing spark) is induced, check transmitter section in ignition distributor (5) and secondary winding of ignition coil.

Resistance values ignition coil:

Primary winding terminal 15 and terminal 1 = 0.33–0.46 2

Secondary winding terminal 1 and terminal 4 = 7–12 kQ

Checking dwell angle

Note: The dwell angle (timing angle) cannot be adjusted. The inspection serves to check function of switchgear (dwell angle control).

Connect dwell angle measuring instrument (Connection similar to Sl-standard switchgear).

Nominal value at

Engine speed Dwell angle

1500+50/min 25-—-39° 5000+50/min’) 33–40°

1) Check at 5000/min only if complaints are about misfiring at high speeds.

If this value is not attained when measuring dwell angle, check ignition distributor transmitter section first. If transmitter section is in order, exchange switchgear.

Testing breakerless transistorized ignition system TSZ 4 – rysunek

Testing ignition distributor transmitter section

Pull off control line of ignition distributor on switchgear and connect ohmmeter.

1 Test transmitter resistance between terminal 7 and 31d.

Nominal value: 600 + 100 Q

Testing breakerless transistorized ignition system TSZ 4 – rysunek

Note: On cold engine the ohmic value should be in Ohmmeter connection for testing transmitter resistance lower half of specified value, on warm engine in upper half.

my

2 Test transmitter coil including control line for ground connection.

Nominal value: terminal 7 and ground = °°

3 Check transmitter section for mechanical damage. There should be an air gap between rotor and stator.

Note: If transmitter section is defective, exchange 6432/1 complete ignition distributor.

Ohmmeter connection for testing ground connection