Checking and machining valves

WIS 05-280

Data

Engines ValveHeight ‘’h’’ of valve retainer (Fig.)Adjusting angie ‘a’ forValve stem dia.Valve seat platingFilled-in sodiumValve length
when newlimitmachining
valuevalve

Intake valves

115.923/926 44.30 . 115.938/939 44.10 with 128

15 1.0 ago+15° 8.97 __ without _ 47.10 8.95 115.951/954 46.50″ without

Exhaust valves

115.923/926 115.938/939 37.20 10.96 ! 37.00″ 2.5 2.0 459 +15 jooa” with with 113.2 . 0 +15″ . A ! 115.951/954

Width of valve seat intake 1.8—-3 exhaust 1.5–2.5

Permissible runout on valve stem and valve seat max. 0.03

Conventional tools

e.g. made by Krupp, D—5309 Meckenheim Valve cone grinder model VS or e.g. made by Hunger, D—8000 Miinchen 70 Valve cone machining tool type VKDR1, order No. 203.00.200

Note Exhaust valves are filled with sodium!

When scrapping valves, pay attention to safety rules. Do not melt valves filled with sodium since there is a risk of explosion and do not use such valves for making tools (punch etc.), without first removing filled-in sodium.

Be careful when removing sodium from valves, since sodium mixed with water and watery solutions reacts heavily explosive, while the resulting hydrogen gas may cause fires.

Sodium from cut-up or broken-up valves can be neutralized in the mixture comprising 2 liters spirit of alcohol and 1 liter of water put into a vessel and placed in the open air.

Valves filled with sodium can be collected and shipped for neutralizing to: Garantieprifstelle Werk StuttgartUntertirkheim.

1 Clean valves and check visually.

Valves with a burnt valve retainer, with unsufficient height ‘’h’’ of valve retainer and valves with worn-out or scored valve stem should be replaced.

Checking and machining valves – rysunek

2 Measure runout on valve stem. tf runout exceeds 0.03 mm, replace valve.

Checking and machining valves – rysunek

3 Machine valve seat.

Refer to operating instructions of machining tool and make sure of 45° adjusting angle.

4 Measure runout on valve seat and height ‘’h” of valve retainer.

When the limit values are attained, replace valve.