Reconditioning of coolant pump

Self-made tools

WIS 20-220 – rysunek

Spacing plate b=1mm 1206 $9197)

WIS 20-220 – rysunek

peo BO

WIS 20-220 – rysunek

Installation sleeve

WIS 20-220 – rysunek

1 Flange (attachment fan, oTVOND Counter-ring hub ring and pulley) Sealing ring N aw Coolant pump shaft with Impeller compact bearing 22.8—23.2 mm Bearing housing 2mm Slide ring sealing Vent bores

Disassembly

1 Support bearing housing with pertinent tubing and press-out coolant pump shaft by means of a mandrel.

WIS 20-220 – rysunek
WIS 20-220 – rysunek

2 Apply light hammer blows at several points between bearing housing and sliding ring seal to cancel the preload and force sliding ring seal out.

3 Force counter ring out of impeller.

WIS 20-220 – rysunek

Note: Replace coolant pump shaft with compact bearing and flange following disassembly on principle.

4 Force-in new compact bearing flush with bearing housing by means of a tube positioned against outer race.

Attention!

WIS 20-220 – rysunek

Do not press against coolant pump shaft.

5 Lightly coat mounting bore of sliding ring seal in bearing housing with sealing compound (part No. 001 989 25 20).

Force-in or knock-in sliding ring seal with pressing-in sleeve.

Attention! Support only against bearing housing and not against coolant pump shaft.

WIS 20-220 – rysunek

6 Coat O-ring on counter-ring with brake cylinder paste and push with chamfered side (arrow) into thoroughly cleaned receiving bore in impeller.

WIS 20-220 – rysunek

7 Clean sealing surfaces of counter-ring and sliding ring seal dust-free using a chamois cloth.

8 Degrease both shaft studs of coolant pump shaft and bore in impeller.

WIS 20-220 – rysunek

9 Press-on impeller flush with coolant pump shaft, while supporting coolant pump shaft.

10 Heat flange on a hot plate up to approx. 300 °C (annealing color dark — up to light blue).

Place heated flange on a recessed base. Hold spacing plate on coolant pump shaft, slip coolant pump shaft on bore of flange and apply a blast of compressed air against flange. Wait for a few seconds until flange is firm and then immediately cool in water bath.