WIS 15-570

WIS 15-570

Note If the jobs described in job No. 07.2–125 have already been completed and the cold start and warmup characteristics are not yet in order, a temperaturecontrolled ignition switchover can be subsequently and individually installed.

Operation

To improve driving characteristics in warm-up stage the firing point is adjusted 8–12° in direction of advance up to approx. + 40 °C coolant temperature in addition to centrifugal force adjustment via vacuum control unit on ignition distributor.

When the cold engine is started, the vacuum flows from carburetor (1) via check valve (3) to vacuum control unit on ignition distributor.

WIS 15-570 – rysunek

wsitt/vi

Carburetor Sag aw Check valve Ignition distributor Thermovalve = red = purple ws = white

The check valve (3) serves to maintain the vacuum and to adjust the firing point 8–12° in direction of advance.

As soon as a coolant temperature of approx. + 40 °C is attained, the thermovalve (5) opens and the vacuum will be reduced in direction of carburetor depending on operation condition.

The vacuum advance is now controlled in dependence of throttle valve position of carburetor.

15,.3-570/1 F2

Installation

WIS 15-570 – rysunek

Attention! Install check valve (3) in such a manner that passage toward carburetor is provided.

WIS 15-570 – rysunek

Installation layout in model 115 OANONW Check valve Thermovalve (40 + 3 °C) To ,,slanted”’ connection on thermovalve To vacuum connection ignition on carburetor Line to ignition distributor

Installation layout in model 123 DAyYONw Check valve Thermovalve (40 + 3 °C) To ,,slanted’’ connection on thermevalve To vacuum connection for ignition on carburetor Line to ignition distributor

WIS 15-570 – rysunek

Installation layout model 115 or 123, if no unused bore for thermovalve is available on intake manifold.

WIS 15-570 – rysunek

For mounting thermovalve (5) in cylinder head, knock threaded bushing (arrow) into existing bore. For knocking-in, screw threaded bushing on a screw M 10 x 1 to prevent damage to threaded bushing.

Spare parts

Designation Part No.

Thermovalve (40 + 3 °C) 000 140 33 60 Check valve 116 800 03 78 Rubber distributing member (3 outlets) 11707801 45 Threaded bushing 115 016 00 50

15,.3-570/3 F2