Checking, renewing and tightening connecting rod bolts
WIS 03-310
Dimensions of connecting rod bolt
Part no. Thread dia Necked-down dia. c when new Min. necked-down dia. (fig. item 1) c
615 038 02 71 M 10x 1 8.4–0.1 8.0
45 000 N Installation pressure of connecting rod bolt
Tightening of connecting rod nuts
Initial tightening torques 40–50 Nm
90-100° Angle of rotation torque
Self-made tool
refer to fig. item 3 Steel plate
Checking
1 Measure minimum necked-down dia. prior to reuse.
Note: Replace connecting rod bolt if the minimum necked-down dia. of 7.2 mm is attained or less than that.
Knock out connecting rod bolt only when it is about to be replaced.
Replacement
2 Knock out connecting rod bolts.
3 Press new connecting rod bolts into connecting rod at approx. 45 000 N or knock in with a hammer and a punch.
When knocking in or pressing in connecting rod bolts, set connecting rod on a ground steel plate.
Hole spacing a = 67 mm Bore b=11mm
Tightening
4 Lubricate nuts and threaded support.
5 Tighten connecting rod nut to 40—50 Nm initial torque and then to 90—100° angle of rotation torque.
Attention! Tighten connecting rod bolts knocked with a hammer
for the first time to 6(0—70 Nm initial torque and
90–100° angle of rotation torque.
This specification must be strictly observed, since otherwise the connecting rod nuts may become loose.
Note: If no angle of rotation tool is available, the connecting rod nuts can also be tightened by means of a normal socket wrench with tommy bar in one step by an angle of 90-100°. This angle should be estimated as accurately as possible. To eliminate angle
of rotation errors, do not use torque wrench for tight-