Checking, renewing and tightening connecting rod bolts

WIS 03-310

Dimensions of connecting rod bolt

Part no. Thread dia Necked-down dia. c when new Min. necked-down dia. (fig. item 1) c

615 038 02 71 M 10x 1 8.4–0.1 8.0

45 000 N Installation pressure of connecting rod bolt

Tightening of connecting rod nuts

Initial tightening torques 40–50 Nm

90-100° Angle of rotation torque

Self-made tool

refer to fig. item 3 Steel plate

Checking, renewing and tightening connecting rod bolts – rysunek

Checking

1 Measure minimum necked-down dia. prior to reuse.

Checking, renewing and tightening connecting rod bolts – rysunek

Note: Replace connecting rod bolt if the minimum necked-down dia. of 7.2 mm is attained or less than that.

Knock out connecting rod bolt only when it is about to be replaced.

Replacement

Checking, renewing and tightening connecting rod bolts – rysunek

2 Knock out connecting rod bolts.

3 Press new connecting rod bolts into connecting rod at approx. 45 000 N or knock in with a hammer and a punch.

When knocking in or pressing in connecting rod bolts, set connecting rod on a ground steel plate.

Hole spacing a = 67 mm Bore b=11mm

Tightening

Checking, renewing and tightening connecting rod bolts – rysunek

4 Lubricate nuts and threaded support.

5 Tighten connecting rod nut to 40—50 Nm initial torque and then to 90—100° angle of rotation torque.

Attention! Tighten connecting rod bolts knocked with a hammer

for the first time to 6(0—70 Nm initial torque and

90–100° angle of rotation torque.

This specification must be strictly observed, since otherwise the connecting rod nuts may become loose.

Note: If no angle of rotation tool is available, the connecting rod nuts can also be tightened by means of a normal socket wrench with tommy bar in one step by an angle of 90-100°. This angle should be estimated as accurately as possible. To eliminate angle

of rotation errors, do not use torque wrench for tight-

ening according to angles of rotation.