Checking, correcting choke housing mark

WIS 07.2-142

Special tool

Checking, correcting choke housing mark – rysunek
Checking, correcting choke housing mark – rysunek

Removal

1 Remove choke cover.

For this purpose, pinch coolant hoses for heating choke cover with a clamp and pull from choke cover (18). – 000 589 40 37 00

Pull off double plug (84), unscrew fastening screws (24) and remove choke cover together with insulating gasket.

Checking, correcting choke housing mark – rysunek

2 Remove choke housing.

On vehicles in national version with float chamber external venting (161), pull off hose on choke housing.

Checking, correcting choke housing mark – rysunek

If required, pull off vacuum line on pulldown cover.

Disconnect connecting rod (26) on choke rod (85). Unscrew fillister head screw (17) and remove choke housing (16).

Checking, correcting choke housing mark – rysunek

Checkup

3 Check choke cover mark and make new mark, if required (calibration of bimetallic spring in choke cover).

For this purpose, choke cover should have a test

Checking, correcting choke housing mark – rysunek

temperature of +20 °C. Place choke cover with insulating gasket on choke housing and turn slowly to the right until choke rod (85) rests approximately in center (arrows) of second-highest detent (pulldown position) of fast idle cam (87).

In this position, check choke cover mark (arrow) and punch in new mark, if required. Remove old marking notch on choke cover.

Note: To prevent faulty calibration, repeat this checkup.

Installation

4 Install choke housing and choke cover in vice versa sequence (item 1 and 2). Use new gasket.

Attention! Do not forget insulating gasket between choke cover and choke housing.

5 Adjust choke (07.2–125).