WIS 09-405
WIS 09-405
A. Model 115 (thermostat)
Removal
1 Compress compression spring (5) and push actuating pin (6) away from air valve shaft and out of fastening eye.
2 Pull actuating pin (6) with guide sleeve (7) and compression spring (5) out of actuating pin of thermostat.
3 Unscrew square nut (8). Remove warm air hose (4) and fresh air duct.
4 Remove thermostat from inside out of intake pipe.
Attention! Do not twist or push out plastic fastening nut (9).
Installation
5 Screw thermostat from inside into plastic fastening nut (9) until thermostat projects 7-8 mm out of plastic fastening nut. Lock thermostat in position by counterlocking square nut (8).
6 Install actuating pin (6) with guide sleeve (7) and compression spring (5).
B. Model 123 (temperature regulator)
Removal
1 Pull vacuum lines from temperature regulator.
2 Remove air cleaner.
3 Slightly open clips of holder with screwdriver (arrow) and remove temperature regulator through air outlet funnel.
Installation
4 For installation proceed vice versa, while paying attention to layout of vacuum lines.