Subsequent installation of cyclonic air cleaner

WIS 09-412

Note To increase the life of air cleaner element in areas with high dust fallout, a cyclonic filter (5) can be subsequently installed in front of air cleaner.

Larger dust particles are separated in outward direction in a swirling motion prior to entering air cleaner. The cyclonic filter requires no maintenance.

Subsequent installation of cyclonic air cleaner – rysunek

Simultaneously, it will be of advantage to install an air cleaner element with a reinforcement of perforated sheet metal, as a protection against damage during frequent intermediate cleaning jobs.

Installation

1 Remove intake manifold (1) and warm air hose between intake manifold and exhaust manifold.

Note: When installing a cyclonic air cleaner, the intake air preheater is inoperative, because a dust separating valve (4) is installed on connection for warm air hose.

Subsequent installation of cyclonic air cleaner – rysunek

2 Screw on cyclonic air cleaner (5) instead of removed intake pipe on air cleaner housing. Simultaneously install air cleaner element with reinforcement of perforated sheet metal.

Note: If the fastening points on air cleaner housing are not in alignment with those on cyclonic air cleaner, displace holes on air cleaner housing, if applicable.

Spare parts

Designation Part No.

Cyclonic air cleaner 000 094 08 05 Air cleaner element 000 094 1005 (reinforced with perforated sheet metal)