Checking choke system

WIS 07.3-125

Test values in bar gauge pressure

Checking choke system – rysunek

Engine

System pressure at idle at operating temperature

Control pressure at idle engine at operating

Control pressure according to ambient temperature at idle min. 0.5 with engine cold (refer to diagram)

Starting voltage 10V

i) lf the control pressure is not attained, check intake manifold vacuum (section ‘Checking control pressure at idle with engine at operating temperature’).

Special tool

Pressure measuring device – 102 589 00 21 00

4 74 11004-9447

Conventional tools

Voltmeter and ohmmeter

Revolution counter

Checking

1 Pull cable plug from warm-up compensator and from cold starting valve.

Checking choke system – rysunek

2 Checking starting voltage.

Pull plug from ignition transmitter on switching unit (green cable) or plug protective plug, part no. 102 589 02 21 00, on diagnosis socket.

Operate starter for a short moment while reading voltage. Nominal value min. 10 Volts. If nominal value is not attained, test battery, charge or replace, if required.

Checking choke system – rysunek

3 Check air flow sensor plate and control piston for easy operation, check fuel pressures and for internal leaks, as well as stabilizing time of warm-up compensator (07.3—120).

Checking cold-starting valve for function and leaks

4 Unscrew fuel line on cold-starting valve (98) and remove cold-starting valve.

5 Loosen fuel line (arrow) on fuel distributor and turn in such a manner that the cold starting valve can be again connected. Then hold cold starting valve into a container.

Checking function

6 Switch-on ignition.

7 Connect cold starting valve with separate cable to B + and ground. Cold starting valve should eject in shape of cone.

Attention! Connect cable first to cold starting valve so that no sparking occurs.

No separate cable need be used below +15 °C, plugon cable plug instead and pull cable plug from safety switch.

Checking for leaks

8 Loosen separate cable connection on cold starting valve. Dry cold starting valve on nozzle. No drops should form.

9 Switch off ignition.

10 Mount cold starting valve with new seal.

11 Plug cable plug on safety switch and on coldstarting valve again.

Testing thermo time switch

Checking choke system – rysunek

The cold starting valve is actuated by closed thermo time switch only at coolant temperatures below +15 °C.

The actuating time increases with decreasing temperature and attains approx. 12 seconds at —20 °C.

99 Thermo time switch

Testing below +15 °C coolant temperature

12 Connect voltmeter to connection of cold starting valve.

13 Actuate starter. Depending on coolant temperature, voltmeter should then indicate 10 Volts for a given period.

The switching time increases with decreasing temperature by approx. 1.5 seconds per 5 °C.

e.g. + 15 °C =0 seconds +10 °C=1.5 seconds

It is recommended to test thermo time switch additionally with an ohmmeter for this test.

Test value below +15 °C:

Connection G-ground = approx. 48 22

Connection W-ground = approx. 02

(Contacts in switch closed).

Testing above +15 °C coolant temperature

Above +15 °C coolant temperature the thermo time switch can be tested only by means of an ohmmeter. For this purpose, pull plug from thermo time switch.

Checking choke system – rysunek

Test values above +15 °C:

Connection G-ground = approx. 62 2 Connection W-ground = approx. 270 Q

9 pp

(Contacts in switch open). Lo

Re-attach plug.

98 Cold starting vaive 99 Thermo time switch c To terminal 50

Testing cutoff point of auxiliary air valve

14 Following a cold start, the engine speed should amount to approx. 800—1000/min. The speed will then increase to approx. 1200—1300/min, and will drop to normal idle speed at approx. 70 °C.

15 Stop engine. Disconnect pressure measuring device while catching fuel with a rag.

16 Connect fuel lines, run engine once again and check all fuel connections for leaks.