Testing breaker-controlled transistorized ignition (USA)
WIS 07.5-520
Conventional tools
1 voltmeter, measuring range O—3 V, O—15 V with 0.1 V scale graduation
1 ohmmeter, measuring range starting 0.1 ohm
1. Testing pre-resistors
Loosen line connection on one connection of resistor about to be tested.
Measure resistance with ohmmeter.
Pre-resistor Resistor rated value at 20 °C
0.4 ohm 0.4 + 0.05 ohm 0.6 ohm 0.6 + 0.05 ohm
Values on warmer pre-resistors will be slightly higher.
2. Testing ignition coil
Insulation test
Separate ignition coil from vehicle circuits by removing terminals 1, 15 and 4.
Connect engine tester to ignition coil. Perform test according to operating instructions.
Whenever possible, test ignition coil with a suitable engine tester (e.g. SUN 745 or 1130) under operating conditions. This will show above all insulation damage, ground and winding shorts.
Evaluate voltage flow on scope according to the following illustration.
20x o
5 >
ii
Selection Line-up Fault Voltage below 20 kv, less than 8 voltage peaks Cause Interrupted winding, winding short or insulation damage against ground Remedy Renew ignition coil
Evaluation
The ignition coil is perfect, if the first oscillation attains 20 kv, followed by min. 8 voltage peaks. If this value is not attained, replace ignition coil.
Resistance test
Resistance rated value at 20 °C
Primary winding measured between 0.38–0.45 ohm terminal 1 and terminal 2
Secondary winding measured between 8–11 kohm terminal 1 and terminal 4
Measuring values are slightly higher when ignition coil is warm.
3. Testing breaker point
For perfect functioning of transistorized systems the transfer resistance on breaker point should not be too high. To check, measure voltage drop at closed breaker point.
Connect voltmeter: + to cable connector (= terminal 7 or TD on switchgear) — to ground
Voltage readout max. 0.3 volt.
If this value is exceeded, install a new breaker point.
4. Testing switchgears and line connections
Test for voltage on switchgear and whether the switching transistor permits passage of ignition coil primary current or locks at pertinent activation. The primary current will not be measured directly, but the voltage drop caused by this current for the sake of simplicity.
The test is made with the engine stopped and the ignition switched on.
Test voltage drop at input of 0.4 ohm resistor with
breaker point closed.
Connect voltmeter: + to input pre-resistor 0.4 ohm — to ground
The voltage drop may amount to max. 0.4 volt.
If voltage drop is too high, test cable and cable connections.
4.1 Standard switchgears (SI)
Checking line connections
Pull 4-pole connecting plug from switchgear and test with voltmeter whether a battery voltage of 11.8–13 volts is available at terminal 15 and terminal 16 on 4-point plug with the ignition switched on.
— to ground
If no voltage is measured, check all connections from input 0.4 ohm resistor to switchgear.
Then reattach 4-point round plug to switchgear.
Voltage with breaker point open
This will test tripping characteristics of transistor.
Connect voltmeter: + to terminal 1 ignition coil — to ground
Battery voltage should be available at terminal 1, i.e. readout = 11.8–13 volts.
If not, replace switchgear.
Voltage with breaker contact closed
Voltmeter connected as before. Voltage at terminal 1 ignition coil = 0.7–1.5 volts.
With breaker point closed, terminal 15 of ignition coil will show 3.6–4.6 volts, with open breaker point battery voltage.
If not, replace switchgear.
Layout of transistorized system with switchgear in model 114.060/073 aOkWwNn— Standard switchgear Ignition coil Pre-resistor 0.4 ohm Pre-resistor 0.6 ohm Cable shoe for test connection (cable color green/yellow}
Test values for switchgear test
Measuring points of associated voltage values for transistorized systems
| Voltmeter Minus to | Breaker point | Rated voltage values SI standard transistorized system | Voltage values beyond rated range: Causes, remedies |
| closed | max. 0.4 V under battery voltage | With correct battery voltage: voltage drop battery — 0.4 ohm Pre-resistor too high caused by transfer resistances (corrosion), line interruption etc. | |
| without signifi- cance | battery voltage | With correct voltage on 0.4 ohm pre-resistor: Parallel resistance or circuit interruption between 0.4 ohm pre-resistor input and terminal 15 or terminal 16 | |
| ground | closed closed | 0–0.3 V 3.6–4.6 V | Voltage value higher: transfer resistance on breaker point too high. Replace breaker point With correct voltage value on switch- gear and on terminal 7 or TD: |
| open | battery voltage | Switchgear defective Replace switchgear | |
| closed open | 0.7-15V battery voltage | ||