Testing breaker-controlled transistorized ignition (USA)

WIS 07.5-520

Conventional tools

1 voltmeter, measuring range O—3 V, O—15 V with 0.1 V scale graduation

1 ohmmeter, measuring range starting 0.1 ohm

1. Testing pre-resistors

Loosen line connection on one connection of resistor about to be tested.

Measure resistance with ohmmeter.

Pre-resistor Resistor rated value at 20 °C

0.4 ohm 0.4 + 0.05 ohm 0.6 ohm 0.6 + 0.05 ohm

Values on warmer pre-resistors will be slightly higher.

2. Testing ignition coil

Insulation test

Separate ignition coil from vehicle circuits by removing terminals 1, 15 and 4.

Connect engine tester to ignition coil. Perform test according to operating instructions.

Whenever possible, test ignition coil with a suitable engine tester (e.g. SUN 745 or 1130) under operating conditions. This will show above all insulation damage, ground and winding shorts.

Evaluate voltage flow on scope according to the following illustration.

Testing breaker-controlled transistorized ignition (USA) – rysunek
Testing breaker-controlled transistorized ignition (USA) – rysunek

20x o

5 >

ii

Selection Line-up Fault Voltage below 20 kv, less than 8 voltage peaks Cause Interrupted winding, winding short or insulation damage against ground Remedy Renew ignition coil

Evaluation

The ignition coil is perfect, if the first oscillation attains 20 kv, followed by min. 8 voltage peaks. If this value is not attained, replace ignition coil.

Resistance test

Resistance rated value at 20 °C

Primary winding measured between 0.38–0.45 ohm terminal 1 and terminal 2

Secondary winding measured between 8–11 kohm terminal 1 and terminal 4

Measuring values are slightly higher when ignition coil is warm.

3. Testing breaker point

For perfect functioning of transistorized systems the transfer resistance on breaker point should not be too high. To check, measure voltage drop at closed breaker point.

Connect voltmeter: + to cable connector (= terminal 7 or TD on switchgear) — to ground

Voltage readout max. 0.3 volt.

If this value is exceeded, install a new breaker point.

4. Testing switchgears and line connections

Test for voltage on switchgear and whether the switching transistor permits passage of ignition coil primary current or locks at pertinent activation. The primary current will not be measured directly, but the voltage drop caused by this current for the sake of simplicity.

The test is made with the engine stopped and the ignition switched on.

Test voltage drop at input of 0.4 ohm resistor with

breaker point closed.

Connect voltmeter: + to input pre-resistor 0.4 ohm — to ground

The voltage drop may amount to max. 0.4 volt.

If voltage drop is too high, test cable and cable connections.

4.1 Standard switchgears (SI)

Checking line connections

Testing breaker-controlled transistorized ignition (USA) – rysunek

Pull 4-pole connecting plug from switchgear and test with voltmeter whether a battery voltage of 11.8–13 volts is available at terminal 15 and terminal 16 on 4-point plug with the ignition switched on.

— to ground

If no voltage is measured, check all connections from input 0.4 ohm resistor to switchgear.

Then reattach 4-point round plug to switchgear.

Voltage with breaker point open

This will test tripping characteristics of transistor.

Connect voltmeter: + to terminal 1 ignition coil — to ground

Battery voltage should be available at terminal 1, i.e. readout = 11.8–13 volts.

If not, replace switchgear.

Voltage with breaker contact closed

Voltmeter connected as before. Voltage at terminal 1 ignition coil = 0.7–1.5 volts.

With breaker point closed, terminal 15 of ignition coil will show 3.6–4.6 volts, with open breaker point battery voltage.

Testing breaker-controlled transistorized ignition (USA) – rysunek

If not, replace switchgear.

Layout of transistorized system with switchgear in model 114.060/073 aOkWwNn— Standard switchgear Ignition coil Pre-resistor 0.4 ohm Pre-resistor 0.6 ohm Cable shoe for test connection (cable color green/yellow}

Test values for switchgear test

Measuring points of associated voltage values for transistorized systems

Voltmeter Minus toBreaker pointRated voltage values SI standard transistorized systemVoltage values beyond rated range: Causes, remedies
closedmax. 0.4 V under battery voltageWith correct battery voltage: voltage drop battery — 0.4 ohm Pre-resistor too high caused by transfer resistances (corrosion), line interruption etc.
without signifi- cancebattery voltageWith correct voltage on 0.4 ohm pre-resistor: Parallel resistance or circuit interruption between 0.4 ohm pre-resistor input and terminal 15 or terminal 16
groundclosed closed0–0.3 V 3.6–4.6 VVoltage value higher: transfer resistance on breaker point too high. Replace breaker point With correct voltage value on switch- gear and on terminal 7 or TD:
openbattery voltageSwitchgear defective Replace switchgear
closed open0.7-15V battery voltage
Testing breaker-controlled transistorized ignition (USA) – rysunek