Renewing contact breakers (breaker points)

WIS 07.5-505

Closing angle (dwell angle)

Normal coil ignition Cs

Closing angle (dwell angle) Change between idle and 3000/min Testing and adjusting value at idle’)

39–42°

1) When installing new breaker points, adjust closing angle (dwell angle) to 42 + 1°.

Transistorized ignition system Cs) GsA

Identification: blue ignition coil, two pre-resistors and transistorized switchgear.

Closing angle (dwell angle) Change between idle and 3000/min Testing and adjusting value at idle”)

34–40°

2) When installing new and when adjusting used breaker points, adjust dwell angle to 34 + 1°.

Special tools

Digital tester – 001 589 54 21 00

N004-7111

Connecting cable – 000 589 04 90 00

Intermediate plug (adaptor) – 000 589 72 63 00

Trigger – 000 589 71 63 00

Conventional tools

Closing angle (dwell angle) measuring instrument

Renewing contact breakers (breaker points) – rysunek

Installation

When renewing contacts, proceed as follows:

1 Wipe contacts prior to installation with a lintfree cloth to remove moisture or grease.

2 Coat slide piece of contact breaker, its bearing point and the cams of the distributor shaft with some Bosch special grease Ft 1 v 4.

Renewing contact breakers (breaker points) – rysunek

3 When closed, contact breakers must be in parallel and at similar level in relation to each other.

Arrow: spot to be greased

Renewing contact breakers (breaker points) – rysunek

4 Set closing angle (dwell angle) to specified value.

Mount protective breaker cap. Cap protects contact against grease, oil or dirt particles.

To make sure that during installation of breaker points the slide piece is greased and the protective cap is mounted, the breaker points are supplied with grease capsule and protective cap from now on.

1 Breaker point 2 Protective cap 115–10 764 3 Grease capsule

5 Check firing point and adjust (07.5—500).