Renewing contact breakers (breaker points)
WIS 07.5-505
Closing angle (dwell angle)
Normal coil ignition Cs
Closing angle (dwell angle) Change between idle and 3000/min Testing and adjusting value at idle’)
39–42°
1) When installing new breaker points, adjust closing angle (dwell angle) to 42 + 1°.
Transistorized ignition system Cs) GsA
Identification: blue ignition coil, two pre-resistors and transistorized switchgear.
Closing angle (dwell angle) Change between idle and 3000/min Testing and adjusting value at idle”)
34–40°
2) When installing new and when adjusting used breaker points, adjust dwell angle to 34 + 1°.
Special tools
Digital tester – 001 589 54 21 00
N004-7111
Connecting cable – 000 589 04 90 00
Intermediate plug (adaptor) – 000 589 72 63 00
Trigger – 000 589 71 63 00
Conventional tools
Closing angle (dwell angle) measuring instrument
Installation
When renewing contacts, proceed as follows:
1 Wipe contacts prior to installation with a lintfree cloth to remove moisture or grease.
2 Coat slide piece of contact breaker, its bearing point and the cams of the distributor shaft with some Bosch special grease Ft 1 v 4.
3 When closed, contact breakers must be in parallel and at similar level in relation to each other.
Arrow: spot to be greased
4 Set closing angle (dwell angle) to specified value.
Mount protective breaker cap. Cap protects contact against grease, oil or dirt particles.
To make sure that during installation of breaker points the slide piece is greased and the protective cap is mounted, the breaker points are supplied with grease capsule and protective cap from now on.
1 Breaker point 2 Protective cap 115–10 764 3 Grease capsule
5 Check firing point and adjust (07.5—500).