Checking and adjusting closing angle (dwell angle) and firing point

WIS 07.5-500

Closing angle (dwell angle)

Normal coil ignition Cs)

Closing angle (dwell angle) Testing and adjusting value at idle’) Change between idle and 3000/min

39–42° max. + 3°

1) When installing new breaker points, adjust closing angle (dwell angle) to 42 + 1°.

Transistorized ignition system Cs) Gsa)

Identification: blue ignition coil, two pre-resistors and transistorized switchgear.

Closing angle (dwell angle) Testing and adjusting value at idle”) Change between idle and 3000/min

30–40° max. + 3°

2) When installing new and when adjusting used breaker points, adjust closing angle (dwell angle) to 34 + 1°.

Firing point

Ignition Adjusting value Test value Vacuum adjustment Installation value of distributor of firing point Ignition adjustment after ignition distributor Bosch no. without vacuum at Starting speed

with vacuum 1500/min 3000/min 4500/min “retard” “advance” without at idle at idle at 4500/min ; vacuum (total) CS 1976 0231309001 TDC 11-172 26–30 —-26–30° 46° 812° 5° before TDC (3442 ©) 1976 0 231 311001 7° before TDC 10–16° 26–33° 29–35° – – 7° before TDC

1973/74 0 231 310 002 4° after TDC 13–17° 31–35° 37–41° 9–13° – 7° before TDC @s) 1975/76

0 231 311001 7° before TDC 10—16° 26-33° 29-35° – – 7° before TDC

Special tools

Sw Nob Nee a Digital tester — – 001 589 54 21 00

Connecting cable – 000 589 04 90 00

Intermediate plug (adaptor) – 000 589 72 63 00

Trigger – 000 589 71 63 00

Conventional tools

Revolution counter, stroboscope, closing angle (dwell angle) measuring instrument

Checking and adjusting closing angle (dwell angle) and firing point – rysunek

1 Measure closing angle (dwell angle) at idle speed.

2 Measure closing angle (dwell angle) change between idle speed and 3000/min, max. change + 3°.

3 Adjust closing angle (dwell angle), if required or replace breaker points (07.5—505) .

With used breaker points, the closing angle (dwell angle) can be adjusted only with transistorized ignition.

Large dwell angle — small point spacing Small dwell angle — large point spacing

Checking and adjusting firing point

4 Measure firing point with stroboscope or digital tester at specified speed with or without vacuum.

Checking and adjusting closing angle (dwell angle) and firing point – rysunek

5 Loosen ignition distributor and set adjusting value of firing point by turning ignition distributor.

Screw down ignition distributor and check firing point.

6 Check centrifugal and vacuum adjustment of ignition distributor. For this purposé, run through specified test values with or without vacuum adjustment.