Checking and adjusting closing angle (dwell angle) and firing point
WIS 07.5-500
Closing angle (dwell angle)
Normal coil ignition Cs)
Closing angle (dwell angle) Testing and adjusting value at idle’) Change between idle and 3000/min
39–42° max. + 3°
1) When installing new breaker points, adjust closing angle (dwell angle) to 42 + 1°.
Transistorized ignition system Cs) Gsa)
Identification: blue ignition coil, two pre-resistors and transistorized switchgear.
Closing angle (dwell angle) Testing and adjusting value at idle”) Change between idle and 3000/min
30–40° max. + 3°
2) When installing new and when adjusting used breaker points, adjust closing angle (dwell angle) to 34 + 1°.
Firing point
Ignition Adjusting value Test value Vacuum adjustment Installation value of distributor of firing point Ignition adjustment after ignition distributor Bosch no. without vacuum at Starting speed
with vacuum 1500/min 3000/min 4500/min “retard” “advance” without at idle at idle at 4500/min ; vacuum (total) CS 1976 0231309001 TDC 11-172 26–30 —-26–30° 46° 812° 5° before TDC (3442 ©) 1976 0 231 311001 7° before TDC 10–16° 26–33° 29–35° – – 7° before TDC
1973/74 0 231 310 002 4° after TDC 13–17° 31–35° 37–41° 9–13° – 7° before TDC @s) 1975/76
0 231 311001 7° before TDC 10—16° 26-33° 29-35° – – 7° before TDC
Special tools
Sw Nob Nee a Digital tester — – 001 589 54 21 00
Connecting cable – 000 589 04 90 00
Intermediate plug (adaptor) – 000 589 72 63 00
Trigger – 000 589 71 63 00
Conventional tools
Revolution counter, stroboscope, closing angle (dwell angle) measuring instrument
1 Measure closing angle (dwell angle) at idle speed.
2 Measure closing angle (dwell angle) change between idle speed and 3000/min, max. change + 3°.
3 Adjust closing angle (dwell angle), if required or replace breaker points (07.5—505) .
With used breaker points, the closing angle (dwell angle) can be adjusted only with transistorized ignition.
Large dwell angle — small point spacing Small dwell angle — large point spacing
Checking and adjusting firing point
4 Measure firing point with stroboscope or digital tester at specified speed with or without vacuum.
5 Loosen ignition distributor and set adjusting value of firing point by turning ignition distributor.
Screw down ignition distributor and check firing point.
6 Check centrifugal and vacuum adjustment of ignition distributor. For this purposé, run through specified test values with or without vacuum adjustment.