Removal and installation of catalysts (model year 1980)
WIS 14-200
Tightening torques
| Self-locking nuts on exhaust manifold to exhaust flange | |
| Self-locking hex nuts on lateral support of clamp | |
| Hex bolts of flange connection | 20 |
| Oxygen sensor | 50–60 |
Removal
1 Remove oxygen sensor (16).
2 Remove exhaust system (49—100).
3 On model 116, loosen plug flange connection between underfloor catalyst and center muffler and remove Catalysts by means of a slight turning motion.
Note: If the plug flange connection cannot be separated, heat exhaust pipe. For safety reasons, place a protective panel against frame floor prior to heating pipe.
4 On model 123, loosen flange connection (a) and remove catalysts.
31° Exhaust manifold 33 Primary catalyst 34 Underfloor catalyst a Flange connection on model 123
14.2–200/1 USA 1980/81 F2
Installation
5 Flange catalysts to exhaust system or on model 116 slip catalysts into plug flange connection. Slightly tighten bolts of flange connection.
6 Install exhaust system (49—100).
7 Coat threads of oxygen sensor with hot lubricating paste, part no. 000 989 88 51.
8 Install oxygen sensor.
9 Start engine and check exhaust system for leaks.
14.2–200/2 USA 1980/81 F2