Operation (model year 1973)

WIS 14-050

Federal and California version model year 1973 Federal version model year 1974

A. General

Information plate

Operation (model year 1973) – rysunek

Vehicles are identified by information plate basic color black.

1 Designation of model year

2 Idle speed 3 Firing point at a speed of . . 4 Emission value at idle 5 Valve clearance

Vacuum switch-over valve

In order to distinguish between the function of the individual valves, the filter caps have been color-coded according to valve function.

White cap Valve for ignition retard Grey cap – valve for throttle valve lift Brown cap _ valve for EGR

14,2–050/1 USA 1973/74 F2

Operation Part No. De-energized Energized Color

In a de-energized condition, connection B is 001 540 04 97 white «| Ve lets ra closed. Vacuum connections A and E are connect001 540 07 97 grey ed to each other. When energized, port E is closed and only connection A is open to 1074 S161 — atmosphere.

m Never confuse connections E and A.

In a de-energized condition, connection A is 001 540 11 97 brown open to atmosphere. Connection E is closed. When energized, connections A and E are connected to each other and connection B (atmosphere) is closed.

Never confuse connections E and A.

! A = connection B = connection E = connected to vacuum unit to atmosphere to vacuum source

Do not confuse vacuum connections when mounting valves. Always slip vacuum-carrying line (originating line) on center connection. It is unimportant whether this connection is at top or bottom of valve.

Operation (model year 1973) – rysunek

Test cable

To test the individual components of emission control system use a self-made cable according to drawing.

1 Plug part no. 003 545 28 28 (housing omitted)

2 Cable 1.5 mm?

14,2–050/2_ USA 1973/74 F2

B. Ignition timing

The ignition timing influences the running characteristics of the engine.

Ignition timing in direction of ‘‘retard’’ results in a higher engine temperature, longer periods of dwell and thereby in a reduction of CH and CO values.

Operation (model year 1973) – rysunek

Function diagram

9 Switch-over valve ignition

10 Switch-over valve throttle valve lift

12 Switch-over valve EGR

13 Vacuum switch

31 EGR valve

34 Vacuum connection on intake pipe

35 Check valve

36 Vacuum tank a Vacuum connection air conditioning system b Vacuum connection fuel return valve A Vacuum connection vacuum switch B Vacuum connection ignition

bl = blue br = brown gr = grey ws = white

Vacuum adjustment in direction of “retard’’ becomes effective in gear speeds 1–3 at the following operating conditions:

®@ above 17 °C oil temperature.

© below 100 °C coolant temperature.

@ at an engine speed up to 3400/min.

®@ with air conditioner switched off.

at a vacuum between 0–0.2 bar.

14.2–050/3_ USA 1973/74 F2

Vacuum adjustment in direction of ‘‘retard”’ is switched off and on by means of switch-over valve (9).

Operation (model year 1973) – rysunek

The switch-over valve is controlled via two relays (5 and 5a), by temperature switch (7) in oil filter housing, by temperature switch (8) in sensor box, by RPM-relay (4), by oil pressure switch (16) on automatic transmission and by vacuum switch (13).

4 RPM-relay with two RPM-switches 1800/2000/min and 3000/4000/min

5 Relay box (001 542 14.19) 8-pole plug 5a Relay box (001 542 12 19) 12-pole piug

9 Switch-over valve ignition

10 Switch-over valve throttle valve lift

12 Switch-over valve EGR 13. Vacuum switch

@ Above 17 °C oil temperature, the temperature

Operation (model year 1973) – rysunek

switch (7) is open, the switch-over valve (9) which is controlled via relay box (5) is de-energized. The vacuum flows from intake pipe via switch-over valve to vacuum control unit ignition distributor.

7 Temperature switch 17 °c

Operation (model year 1973) – rysunek

®@ Below 100 °C coolant temperature, the temperature switch (8) is open, the switch-over valve (9) which is controlled via relay box (5a) is de-energized.

1 Telethermometer transmitter 8 Temperature switch 100 °C 32 Temperature switch 65 °C

14,2–050/4 USA 1973/74 F2

Operation (model year 1973) – rysunek

At an engine speed up to 3400/min the RPM-relay (4) is open, the switch-over valve (9) is de-energized.

@ With air conditioner switched off, the switch-over valve (9) is de-energized.

S If the vacuum increases between 0—O.2 bar, the vacuum switch (13) closes, the switch-over valve (9) is de-energized.

Operation (model year 1973) – rysunek

When shifting to 4th speed the oil pressure switch (16) on automatic transmission is closed. The switchover valve (9) is energized via relay box (5a) and the vacuum adjustment in direction of “retard” is cancelled. This will prevent any overheating of engine.

Operation (model year 1973) – rysunek

C. Throttle valve lift

To draw off and burn the vapors generated in crankcase during deceleration (coasting), as well as the fuel particles adhering to intake pipe, the throttle valve is slightly lifted in this driving range.

During deceleration above 200/min above 17 °C oil temperature and below 100 °C coolant temperature the throttle valve of carburetor is slightly lifted by vacuum governor.

Operation (model year 1973) – rysunek

Both temperature switches (7 and 8) are open. The RPM-switch 1800/2000/min in RPM-relay (4) is closed and actuates switch-over valve (10) via relay box (5a).

The switch-over valve (10) is installed in vacuum line between carburetor and intake pipe and interrupts the connection. The diaphragm of the vacuum governor is connected to atmosphere by the switch-over valve (10), the control rod will move outwards.

14.2—-050/5 USA 1973/74 F2

Operation (model year 1973) – rysunek

If the speed drops below 1800/min, the RPM-switch in RPM-relay (4) will open. The switch-over valve (10) is de-energized and the vacuum connection from intake pipe to vacuum governor is re-established. The throttle valve returns to its idle speed position.

D. EGR (exhaust gas recirculation)

To reduce nitrogen oxides in exhaust gases, a portion of the gases from the exhaust manifold is returned to the intake pipe through a valve.

The quantity of the returned exhaust gas is limited and cut off completely in some driving conditions, so that the driving characteristics of the vehicle are not influenced.

EGR valve

EGR components

Operation (model year 1973) – rysunek

EGR valve

The EGR valve controls the volume (amount) of the returned (recirculated) exhaust gases in dependence of the coolant temperature and the vacuum.

14,2-050/6 USA 1973/74 F2

Operation (model year 1973) – rysunek

EGR line

Operation (model year 1973) – rysunek

The EGR line (1) runs from exhaust manifold underneath engine to EGR valve on intake pipe.

EGR is activated:

®@ above 17 °C oil temperature.

® between 65 °C and 100 °C coolant temperature.

@ at a vacuum between 0 and 0.2 bar.

@ at an engine speed up to 3400/min.

If these conditions are met, the switch-over valve (12) is energized.

Operation (model year 1973) – rysunek

31, EGR vaive 34 Vacuum connection on intake pipe

Operation

Temperature switch (7), temperature switch (8) and vacuum switch (13) are open, temperature switch (32) is closed. The switch-over valve (12) is energized and the diaphragm of EGR valve (31) is connected to vacuum tank (36 in right-hand wheel house). EGR valve (31) opens.

E. Choke cover-stepped heater

To improve warming-up characteristics the cover of the automatic choke is heated in two steps. Below 17 °C oil temperature at reduced capacity, above 17 °C oil temperature at normal capacity.

This stepped heater has been installed as standard equipment since January 1974. Subsequent installation is also possible.

14,2–050/7 USA 1973/74 F2

Operation

Operation (model year 1973) – rysunek

RPM-relay with two RPM-switches 1800/2000/min and 3000/3400/min Relay box (001 542 14 19) 8-pole plug Relay box (001 542 12 19) 12-pole plug Switch-over valve ignition Switch-over valve throttle valve lift Switch-over valve EGR Vacuum switch Choke cover resistance Relay choke cover resistance o Relay temperature switch 17 ~C

Below 17 °C oil temperature the oil temperature switch (7) in oil filter housing is closed and relay (52) switches.

The relay for resistance of choke cover (47) connects resistance (46) for reduced heater output.

Above 17 °C oil temperature the temperature switch (7) is open, relay (52) switches and the relay for resistance of choke cover (47) bridges resistance (46).

14.2–050/8 USA 1973/74 F2