Testing starting device (choke) for function (cold start)
WIS 07.2-128
Testing and adjusting values
Voltages measured at battery
| Rest potential | min. 12.2 volts | |
| Starting voltage | min. 10 volts | |
| Regulating voltage alternator | 13.0–14.5 volts | |
| Voltages measured at ignition coil | ||
| Terminal 15 Terminal 1 | Breaker contact ‘‘closed’’ | 3.6–4.6 0.71.5 |
| Terminal 15 Terminal 1 | Breaker contact ‘‘open” | battery voltage a battery voltage |
| Voltage at pre-resistor | —_ OO | |
| Pre-resistor output 0.4 ohm Cable: red/black (Pre-resistor bridge-over) | min. 9.6 volts |
Carburetor
TN control window opening at + 20 °C approx. 2.5 mm
CO value after starting cold engine 7–8 %!)
1) tf the CO value is essentially above upper tolerance, spark plugs have a tendency for sooting, engine starts misfiring. If it is considerably below lower tolerance, starting faults and bypass faults may occur.
Special tools
Digital tester – 001 589 54 21 00
Connecting cable 3 m long – 000 589 04 90 00
Intermediate plug (adaptor) – 000 589 72 63 00
Trigger – 000 589 71 63 00
Conventional test instruments
Voltmeter, revolution counter and CO measuring instrument
Testing
1 Let engine cool down to below + 20 °C. Check whether choke valve (147) is completely closed and has lateral clearance. (Below + 20 °C the choke valve should be completely closed).
2 Remove air filter, pull cable from choke cover heater so that choke valve is not completely opening during the following voltage measurements.
3 Check battery for external condition (visual checkup). Check battery poles for oxidation.
4 Test voltages on battery.
a) Rest potential
Connect voltmeter to battery plus and minus pole, read voltage.
Nominal value: min. 12.2 volts
b) Starting voltage
Pull high-voltage ignition cable 4 out of distributor cover and connect to ground. Operate starting motor while reading voltage.
Nominal value: min. 10 volts
NYUMAMAPWN— TMA Ignition starter switch Pre-resistor 0.4 ohm Pre-resistor 0.6 ohm Ignition coil Standard switchgear Ignition distributor Diagnosis plug To starter terminal 16 To diagnosis socket
5 Test voltages at ignition coil.
a) With breaker contact closed at terminal 15 and terminal 1:
Nominal values: Terminal 15, 3.6–4.6 volts Terminal 1, 0.7–1.5 volts
b) With breaker contact opened at terminal 15 and terminal 1:
Nominal values: Terminal 15 and terminal 1 should be energized by battery voltage.
6 Measure voltage at pre-resistor 0.4 ohm while starting (pre-resistor bridge-over).
Nominal value: min. 9.6 volts
7 Insert high-voltage ignition cable 4 again into distributor cover.
8 Check choke cover preload. Markings (arrow) should be opposite each other.
9 Remove TN choke after loosening fastening screws (arrow) together with coolant hoses.
control piston with slide gauge.
Nominal values: At + 20 °C approx. 2.5 mm. At approx. 0 °C control window should be completely open.
11. Install TN choke and air filter.
12 Check warming-up total mixture without air injection and EGR, adjust. For this purpose, connect CO measuring instrument and make air injection inOperative as described below (for Gs) 1973/74 nothing need be made inoperative):
@) 1976
Pull off blue/purple vacuum line at connecting point (arrow).
CS) 1976, model 114
Pull rubber cap (arrow) from blue/purple vacuum line.
Cs) 1976, model 116
Pull rubber cap (arrow) from blue/purple vacuum line.
@sA California 1974
Pull off red vacuum line at connecting point (arrow).
@s) 1975/76
Pull off blue/purple vacuum line at connecting point (arrow).
Start engine and rapidly depress accelerator upon firing.
Engage driving position for automatic transmission, permit CO value to come to rest and read. (If deviations from tolerance value are high, stop engine immediately, change choke valve gap accordingly and repeat CO test).
Nominal value: 7–8 % CO
Pushing together = leaner
Pushing apart = richer
Screwing out = leaner
Screwing in = richer
Again plug-on vacuum hoses for air injection and EGR (air injection with EGR operative).
13 Again plug-on cable for choke cover heater.
14 Test regulating voltage of alternator.
Note: Prior to testing regulating voltage, check acid density of battery. If acid density (state of charge) of battery is lower than 1.24 kg/dm? in tropical countries, a defective transistor regulator (full regulation) is no longer recognized.
Checkup