Removal and installation of accelerating pump diaphragm

WIS 07.2-154

Testing and adjusting values

Begin of injection immediately

Special tool

Clamp – 000 589 40 37 00

Removal

Removal and installation of accelerating pump diaphragm – rysunek

1 Remove air filter.

2 Remove cover (30) after loosening fastening screws.

3 Remove diaphragm and compression spring.

4 Clean pump chamber.

Installation

5 Install new diaphragm, if required.

Note: Insert compression spring in such a manner that the large diameter faces the pump chamber. When tightening fastening screws of cover, operate throttle valve lever to full extent.

6 Adjust accelerating pump (07.2—150).