Checking fuel pump
WIS 07.2-210
Test values
Measuring point prior to pump inlet
Vacuum (suction end) at starting speed mbar (mm Hg) 335–470 (250-350)
max. pressure drop within 95 (70) first minute mbar (mm Hg)
Measuring point following pump outlet
Delivery pressure (pressure end) at starting speed bar gauge pressure 0.20
max. pressure drop within first minute 0.05 bar gauge pressure
Special tool
Clamp – 000 589 40 37 00
Conventional tool
e.g. made by Bosch, EFAW 177 Fuel pump pressure vacuum tester e.g. made by SUN, VPT 212
Checking vacuum at suction end
1 Short ignition system. For this purpose, connect cable from ground to terminal 1 of ignition coil.
2 Pinch suction hose. Pull off suction and pressure hose.
Connect tester at suction end.
1 Suction hose 2 Pressure hose
3 Crank engine with starting motor until vacuum is no longer increasing. Compare indicated value with rated value. Watch pressure drop.
Checking delivery pressure at pressure end
4 Connect tester at pressure end.
5 Crank engine with starting motor until delivery pressure is no longer increasing. Compare indicated value with rated value. Watch pressure drop. R 07/6447
Note: If the vacuum or delivery pressure is not attained, check whether infiltrated (false) air is sucked in at rubber sealing ring (1). Renew sealing ring, if required, and repeat test.