Checking float chamber external venting system

WIS 07.2-182

Special tool

Clamp – 000 589 40 37 00

Conventional tool

Vacuum tester

Note The float chamber external venting system influences hot start characteristics, fuel consumption, bypass characteristics stage and $1 and driving performance under full load. If the float chamber external venting system is defective, the fuel level in float chamber will be exposed to atmospheric air pressure, the fuel in mixing tubes will rise to an inadmissible level and the engine will be supplied with excessively rich fuel. High fuel consumption and driving faults will result.

Checking float chamber external venting system – rysunek

A. © 1974 California

Function diagram

Float chamber ventilation and

evaporation control system

1 Carburetor

12 Electric switchover valve for EGR

31 EGR valve

34 Vacuum connection on intake

35 Check valve

36 Vacuum supply tank

37 Electric switchover valve for float chamber ventilation

38 Draw-off valve

39 Charcoal canister

b Negative tank vent connection c Air conditioner connection A Vacuum switch connection (EGR) B Draw-off valve connection C_ Decel diverter valve connection, valve, ignition switchover and Line color br = brown gr = grey ws = white

Test conditions: All electric fuses in order. Engine at operating temperature. Sealing at vacuum end of controls for EGR and air conditioner, as well as their operation in order.

Checking float chamber external venting system – rysunek

Test scope

Connect vacuum tester. Run engine at idle, a vacuum should be indicated.

Checking float chamber external venting system – rysunek

Vacuum in order. No vacuum.

1 Check connecting pipe and diaphragm for leaks. For this purpose, pinch vacuum hose at vent valve. If vacuum is now available, attach connecting pipe by glueing with Omnifit or renew diaphragm, respectively.

2 Check all vacuum hoses up to intake pipe for correct layout, condition and tight seat and recondition, if required.

3 Check electric switchover valve (37). For this purpose, switch ignition on and off. The operating noise should now be heard or felt. If not, check whether with the ignition switched on the plug is energized and connected to ground. Renew fuse or establish ground connection, as required. If everything is in order and the switchover valve is nevertheless not yet switching, renew valve since a mechanical defect is indicated.

Pull hose on connection ‘’C’‘ from charcoal canister. With the engine running, blow into hose. There should be no passage and engine should not shut off.
No passage or engine not shutting off.Passage or engine shutting off.
Ae
1, Valve plate not sealing because gasket 2. Valve plate not sealing because it is dis-is wrongly mounted (asymmetric), correct position of gasket, if required. torted. Renew vent valve, if required.
Checking float chamber external venting system – rysunek
Checking float chamber external venting system – rysunek
Checking float chamber external venting system – rysunek

= “P

With the engine running, pull vacuum hose (34) from intake pipe (= full throttle simulation!) and watch vacuum readout. Vacuum should not drop and should remain constant for at least two minutes.

Note: Below 130 mbar, valve plate will no longer close.

Checking float chamber external venting system – rysunek

Vacuum remains Vacuum drops. constant.

1, Check valve (35) leaking, renew if required.

2. Electric switchover valve (37) or (12) leaking. Check for leaks by shorting both switchover valves one after the other by pinching vacuum hoses to localize leaking member. Renew, if required.

Checking float chamber external venting system – rysunek

B. @1975/76, ©) 1976

Function diagram

Float chamber ventilation and fuel

control system

1 Carburetor

33 Vacuum vaive for air injection

35 Check valve

37 Electric switchover valve for float ventilation

38 Draw-off valve

41 Decel diverter valve (air injection) 284 Fuel return valve (vacuum-actuated) b Negative tank vent connection

Line colors bl = blue gn == green gn/vi = green/purple sw = black

Checking float chamber external venting system – rysunek

Test conditions: All electric fuses in order. Engine at operating temperature. Sealing at vacuum end of decel diverter valve (41) and switchover valve (33), as well as their function in order.

Connect vacuum tester. Run engine at idle speed, vacuum should be indicated.a
Vacuum in order.No vacuum.a

1. Check connecting pipe and diaphragm for leaks. For this purpose, pinch vacuum hose at vent valve. If vacuum is now available, attach connecting pipe, glue in with Omnifit or renew diaphragm, as required.

2. Check all vacuum hoses up to vacuum governor for correct layout, condition and tight seat and recondition, if required.

Checking float chamber external venting system – rysunek
Checking float chamber external venting system – rysunek

3. Check electric switchover valve (37). For this purpose, switch ignition on and off, the operating noise should now be heard or felt. If not, check whether with the ignition switched on the plug is energized and connected to ground. Renew fuse, if required or establish ground connection. If everything is in order and the switchover valve is nevertheless not switching, renew valve since a mechanical defect is indicated.

=F “Pr

Checking float chamber external venting system – rysunek

Pull off hose at connection “’C’’ of charcoal canister. With the engine running, blow into hose, there should be no passage and engine should not shut off.

Checking float chamber external venting system – rysunek

No passage and engine Passage or engine not shutting off. shutting off.

Checking float chamber external venting system – rysunek

“SP

1. Valve plate not sealing because gasket is wrongly mounted (asymmetric), correct position of gasket, if required.

2. Valve plate not sealing because it is distorted. Renew vent valve, if required.

—_—

Checking float chamber external venting system – rysunek

With the engine running, pull off vacuum hose (64) (= full throttle simulation!) and watch vacuum readout. Watch vacuum, which should remain constant for at least two minutes.

Note: Below aprrox. 130 mbar, valve plate is no longer closing.

Vacuum remains Vacuum drops. constant.

Checking float chamber external venting system – rysunek

1. Check valve (35) leaking, renew if required.

2. Electric switchover valve (37), decel diverter valve, switchover valve (33) or fuel return leaking at vacuum end. Check for leaks by pinching vacuum hoses one after the other to localize leaking member, renew if required.

End of test