Replacing knock sensors
WIS 15-2183
Operation No. of operation texts and work units or standard texts and flat rates:
Screws (arrows) …. eee ee ee ewes … unscrew, screw in. Tightening torque 20 Nm as reference value. Connector at EZL/AKR control unit ……….. unplug, plug in. Protective hose for cables ………….. … unclip, clip in.
Note The cables of both knock sensors (A16) are combined in the protective hose (corrugated hose). They can only be replaced as a unit.
ote = RA 15.1214-2183/1