Removing and installing exhaust gas recirculation switchover vaive

WIS 14-7692

Removing and installing exhaust gas recirculation switchover vaive – rysunek

Operation no. of operation texts and work units or standard texts and flat rates: 14-7692.

Model 124 Cs) @sa)

Electrical coupling ……………….008at exhaust gas recirculation switchover valve (Y¥27), unplug, plug in. Vacuum hose (tr/vi/br) 2.2… 22… ee ee ee pull off, fit on.

Installation note

Pay attention to colour coding on vacuum hose. Vacuum hose for non-return valve ……….. pull off, fit on. Nuts (arrows) 000 e eee eee eee turn down, turn up. Exhaust gas recirculation switchover valve (Y27) 2. ee eee eee detach at carrier, attach.

wie RA 14.1132-7692/1

KE control unit fault memory read, erase if necessary (see Diagnosis Manual Engine, Volme 2, Register 0).

Note Stored faults which may be caused by disconnected cables or simulation during test work, must be erased in the fault memory after completing all work.

Function diagram air injection and exhaust gas recirculation

Models 124, 126, 201 national version Gs®)

Removing and installing exhaust gas recirculation switchover vaive – rysunek

839 _—_ Exhaust gas recirculation valve 123 Throttle valve body 125 Air pump 126 Air shutoff valve 127 Non-return valve {injected air) 128 Non-return valve (vacuum) 156 Exhaust manifold N3 KE injection system control unit N16 Engine systems control unit MAS Y27 ARF switchover valve Y32 Air pump switchover valve ¥33 Air pump electromagnetic clutch

Note On model 129 the exhaust gas recirculation valve (89) is controlled by a 70/35 °C thermovalve.

wim = RA 14.1132-7692/2