484 Check fluid level of air conditioning system

£4,534

ee _ Revision: Capacity for model 100 added. All models except model 113

Model 100 107, 108, 109, 111 114, 115, 116.036 116.02/032/033 123

484 Check fluid level of air conditioning system – rysunek

1800 g 1000 g 800 g 1200 g Refrigerant R 12 1600 g}) 1) On vehicles with auxiliary fan.

Vehicles without automatic climate control

  • With the engine running and the air conditioning system switched on, check whether the white bal! floats or that the refrigerant flows through free of bubbles.

\f the white bali does not float or the formation of bubbles or foam is observed at the inspection window the air conditioning system contains too little refrigerant.

484 Check fluid level of air conditioning system – rysunek

Note: if necessary, top up the air conditioning system. Model 100 without auxiliary fan In case of a loss of refrigerant of more than 200 g, check the air conditioning system for leaks.

1 inspection window

Model 107 rn tenner tnt

484 Check fluid level of air conditioning system – rysunek
484 Check fluid level of air conditioning system – rysunek
484 Check fluid level of air conditioning system – rysunek
484 Check fluid level of air conditioning system – rysunek

Models 108, 109,111 Models 114, 115 Behr manufacture Lefthand drive

484 Check fluid level of air conditioning system – rysunek
484 Check fluid level of air conditioning system – rysunek

Models 108.016, 108.018, 108.019 Models 114, 115 (except 114.06/07) Thermoking manufacture, only in USA vehicles Righthand drive

Models 108.067, 108.068, 109.057 Models 114.06, 114.07 Thermoking manufacture, only in USA vehicles Righthand drive

484 Check fluid level of air conditioning system – rysunek
484 Check fluid level of air conditioning system – rysunek

Model 116 Lefthand drive Model 123 (mirror image for righthand drive)

Vehicles with automatic climate control

484 Check fluid level of air conditioning system – rysunek
  • Start engine and run at idle speed.

Depress push-button switch “DEF” (blower should run at max. blower stage and the electro-magnetic clutch of compressor should connect).

  • Check fluid level as follows: Pull off electric lines on low pressure switch (25), electromagnetic clutch should then switch off and the refrigerant should flow back to reservoir (refer to arrow).
  • Reattach electric lines, electromagnetic clutch should again connect and the refrigerant should flow past sight gauge free of bubbles.
484 Check fluid level of air conditioning system – rysunek
  • Foam or bubbles at sight gauge are an indication Models 107, 116 that there is not enough refrigerant in system.

Note: |f required, top up. If more than 200 g of refrigerant are lost, check system for leaks.