773 Renew contact breaker points
All gasoline engines Except engines with transistorized ignition without contact
Test values
refer to: Adjust dwell angle and ignition timing Job no. 782
When renewing contacts Observe the following points.
- On ignition distributors with protective cover (1), cover must be removed for replacing contact breaker points. When attaching cover, make sure that cover engages well and will not wipe against distributor shaft.
Protective cover
- Slightly coat slide piece of contact breaker with Bosch special grease Ft 1v4 (refer to drawing); Bosch Order No. for 250 gram tube, 5 700 002 025, remove other grease remainders from distributor.
- Contacts should be in parallel and at similar level in relation to each other when closed. At. max. Opening the basic adjustment is approx. 0.3–0.4 mm.
- On ignition distributors with 2 pairs of contact breaker points, clean connecting cable and isulating plate,
- On vehicles manufactured as from January 1970 the felt in the distributor shaft no longer requires lubrication.
On earlier vehicles,.add about 2 drops of oi/ to felt in distributor shaft and, if installed, to distributor oiler.
- Check and adjust dwell angle and ignition timing (refer to job no. 782).
eee ee 773