{"id":3040,"date":"2023-11-19T13:07:09","date_gmt":"2023-11-19T12:07:09","guid":{"rendered":"https:\/\/mbci.mackuz.ovh\/?p=3040"},"modified":"2023-11-19T13:07:09","modified_gmt":"2023-11-19T12:07:09","slug":"checking-of-expansion-tank-closing-cover","status":"publish","type":"post","link":"https:\/\/mbci.mackuz.ovh\/index.php\/2023\/11\/19\/checking-of-expansion-tank-closing-cover\/","title":{"rendered":"Checking of expansion tank closing cover"},"content":{"rendered":"<p>&nbsp;<\/p>\n<table border=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"top\"><\/td>\n<td colspan=\"6\" valign=\"top\">\n<div>\n<div><\/div>\n<\/div>\n<p>&nbsp;<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"top\"><\/td>\n<td colspan=\"6\" valign=\"top\">\n<div>\n<div><strong>20\u2014430 Checking of expansion tank closing cover<\/strong><\/div>\n<\/div>\n<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"top\"><\/td>\n<td colspan=\"6\" valign=\"top\">\n<div>\n<div><\/div>\n<\/div>\n<p>&nbsp;<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"top\"><\/td>\n<td colspan=\"6\" valign=\"top\">\n<div>\n<div><strong>Expansion tank closing cover<\/strong><\/div>\n<\/div>\n<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"top\"><\/td>\n<td colspan=\"6\" valign=\"top\">\n<div>\n<div><\/div>\n<\/div>\n<p>&nbsp;<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"top\"><\/td>\n<td valign=\"top\">\n<div>\n<div>Pressure relief valve opens at<\/div>\n<\/div>\n<\/td>\n<td colspan=\"2\" valign=\"top\">\n<div>\n<div>new closing cover 1-Oio&#8217;]<sup>5<\/sup> bar gage pressure<\/div>\n<div>used closing cover 1.0\u20140.2 bar gage pressure<\/div>\n<\/div>\n<\/td>\n<td colspan=\"3\" valign=\"top\">\n<div><img decoding=\"async\" src=\"\/warsztat\/silniki\/OM617\/om617%20-%200454-1.jpg\" alt=\"om617 - 0454-1.jpg\" \/><\/div>\n<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"top\"><\/td>\n<td colspan=\"6\" valign=\"top\">\n<div>\n<div><\/div>\n<\/div>\n<p>&nbsp;<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"top\"><\/td>\n<td colspan=\"6\" valign=\"top\">\n<div>\n<div>Vacuum valve starts opening at 0.1 bar vacuum<\/div>\n<\/div>\n<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"top\"><\/td>\n<td colspan=\"6\" valign=\"top\">\n<div>\n<div><\/div>\n<\/div>\n<p>&nbsp;<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"top\"><\/td>\n<td colspan=\"2\" valign=\"top\">\n<div>\n<div><strong>Special tools<\/strong><\/div>\n<\/div>\n<\/td>\n<td colspan=\"2\" rowspan=\"3\" valign=\"top\">\n<div><img decoding=\"async\" src=\"\/warsztat\/silniki\/OM617\/om617%20-%200454-2.jpg\" alt=\"om617 - 0454-2.jpg\" \/><\/div>\n<\/td>\n<td colspan=\"2\" rowspan=\"2\" valign=\"top\">\n<div>\n<div>001 589 48 21 00<\/div>\n<\/div>\n<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"top\"><\/td>\n<td colspan=\"2\" valign=\"top\">\n<div>\n<div>Tester for cooling system<\/div>\n<\/div>\n<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"top\"><\/td>\n<td colspan=\"2\" valign=\"top\">\n<div>\n<div>Double connection for expansion tank closing cover for cooling system tester<\/div>\n<\/div>\n<\/td>\n<td colspan=\"2\" valign=\"top\">\n<div>\n<div><strong>000 589 73 63 00<\/strong><\/div>\n<\/div>\n<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"top\"><\/td>\n<td colspan=\"6\" valign=\"top\">\n<div>\n<div><\/div>\n<\/div>\n<p>&nbsp;<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"top\"><\/td>\n<td colspan=\"4\" valign=\"top\">\n<div>\n<div><strong>Checking pressure relief valve<\/strong><\/div>\n<\/div>\n<\/td>\n<td rowspan=\"2\" valign=\"top\">\n<div><img decoding=\"async\" src=\"\/warsztat\/silniki\/OM617\/om617%20-%200454-3.jpg\" alt=\"om617 - 0454-3.jpg\" \/><\/div>\n<\/td>\n<td rowspan=\"2\" valign=\"top\">\n<div>\n<div><strong>11004-8666<\/strong><\/div>\n<\/div>\n<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"top\"><\/td>\n<td colspan=\"4\" valign=\"top\">\n<div>\n<div>1\u00a0 \u00a0 Attach double connection on tester for cooling system by means of holders.<\/div>\n<div>2\u00a0 \u00a0Place expansion tank closing cover on double connection.<\/div>\n<div>3\u00a0 \u00a0Check by pumping opening pressure.<\/div>\n<\/div>\n<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"top\"><\/td>\n<td colspan=\"6\" valign=\"top\">\n<div>\n<div><\/div>\n<\/div>\n<p>&nbsp;<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"top\"><\/td>\n<td colspan=\"6\" valign=\"top\">\n<div>\n<div><strong>Checking vacuum valve<\/strong><\/div>\n<\/div>\n<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"top\"><\/td>\n<td colspan=\"6\" valign=\"top\">\n<div>\n<div><\/div>\n<\/div>\n<p>&nbsp;<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"top\"><\/td>\n<td colspan=\"3\" valign=\"top\">\n<div>\n<div>The vacuum valve (arrow) should rest against rubber seal, valve should lift easily and snap back upon release.<\/div>\n<\/div>\n<\/td>\n<td colspan=\"3\" valign=\"top\">\n<div><img decoding=\"async\" src=\"\/warsztat\/silniki\/OM617\/om617%20-%200454-4.jpg\" alt=\"om617 - 0454-4.jpg\" \/><\/div>\n<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"top\"><\/td>\n<td colspan=\"6\" valign=\"top\">\n<div>\n<div><\/div>\n<\/div>\n<p>&nbsp;<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"top\"><\/td>\n<td colspan=\"6\" valign=\"top\">\n<div>\n<div>20.8-430\/1 F 2<\/div>\n<\/div>\n<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"top\"><\/td>\n<td colspan=\"6\" valign=\"top\">\n<div>\n<div><\/div>\n<\/div>\n<p>&nbsp;<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>&nbsp; &nbsp; 20\u2014430 Checking of expansion tank closing cover &nbsp; Expansion tank closing cover &nbsp; Pressure relief valve opens at new closing cover 1-Oio&#8217;]5 bar gage pressure used closing cover 1.0\u20140.2 bar gage pressure &nbsp; Vacuum valve starts opening at 0.1 bar vacuum &nbsp; Special tools 001 589 48 21 00 Tester for cooling system Double connection for expansion tank closing cover for cooling system tester 000 589 73 63 00 &nbsp; Checking pressure relief valve 11004-8666 1\u00a0 \u00a0 Attach double connection on tester for cooling system by means of holders. 2\u00a0 \u00a0Place expansion tank closing cover on double connection. 3\u00a0 \u00a0Check by pumping opening pressure. &nbsp; Checking vacuum valve &nbsp; The vacuum valve (arrow) should rest against rubber seal, valve should lift easily and snap back upon release. &nbsp; 20.8-430\/1 F 2 &nbsp; &nbsp; &nbsp; &nbsp;<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_crdt_document":"","footnotes":""},"categories":[55,44],"tags":[],"class_list":["post-3040","post","type-post","status-publish","format-standard","hentry","category-engine-cooling-om617","category-om617"],"aioseo_notices":[],"featured_image_src":null,"author_info":{"display_name":"mackuz","author_link":"https:\/\/mbci.mackuz.ovh\/index.php\/author\/mackuz\/"},"_links":{"self":[{"href":"https:\/\/mbci.mackuz.ovh\/index.php\/wp-json\/wp\/v2\/posts\/3040","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/mbci.mackuz.ovh\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/mbci.mackuz.ovh\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/mbci.mackuz.ovh\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/mbci.mackuz.ovh\/index.php\/wp-json\/wp\/v2\/comments?post=3040"}],"version-history":[{"count":1,"href":"https:\/\/mbci.mackuz.ovh\/index.php\/wp-json\/wp\/v2\/posts\/3040\/revisions"}],"predecessor-version":[{"id":3041,"href":"https:\/\/mbci.mackuz.ovh\/index.php\/wp-json\/wp\/v2\/posts\/3040\/revisions\/3041"}],"wp:attachment":[{"href":"https:\/\/mbci.mackuz.ovh\/index.php\/wp-json\/wp\/v2\/media?parent=3040"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/mbci.mackuz.ovh\/index.php\/wp-json\/wp\/v2\/categories?post=3040"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/mbci.mackuz.ovh\/index.php\/wp-json\/wp\/v2\/tags?post=3040"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}