{"id":2605,"date":"2023-11-14T20:17:02","date_gmt":"2023-11-14T19:17:02","guid":{"rendered":"https:\/\/mbci.mackuz.ovh\/?p=2605"},"modified":"2023-11-14T20:17:02","modified_gmt":"2023-11-14T19:17:02","slug":"removal-and-installation-of-mixture-controller","status":"publish","type":"post","link":"https:\/\/mbci.mackuz.ovh\/index.php\/2023\/11\/14\/removal-and-installation-of-mixture-controller\/","title":{"rendered":"Removal and installation of mixture controller"},"content":{"rendered":"<p>&nbsp;<\/p>\n<table border=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"top\"><\/td>\n<td colspan=\"4\" valign=\"top\">\n<div>\n<div><\/div>\n<\/div>\n<p>&nbsp;<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"top\"><\/td>\n<td colspan=\"4\" valign=\"top\">\n<div>\n<div><strong>07.3\u2014200 Removal and installation of mixture controller<\/strong><\/div>\n<\/div>\n<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"top\"><\/td>\n<td colspan=\"4\" valign=\"top\">\n<div>\n<div><\/div>\n<\/div>\n<p>&nbsp;<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"top\"><\/td>\n<td colspan=\"3\" valign=\"top\">\n<div>\n<div><strong>Tightening torques<\/strong><\/div>\n<\/div>\n<\/td>\n<td valign=\"top\">\n<div>\n<div>Nm<\/div>\n<\/div>\n<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"top\"><\/td>\n<td colspan=\"4\" valign=\"top\">\n<div>\n<div><\/div>\n<\/div>\n<p>&nbsp;<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"top\"><\/td>\n<td colspan=\"3\" valign=\"top\">\n<div>\n<div>Hex. screws mixture controller to air guide housing<\/div>\n<\/div>\n<\/td>\n<td valign=\"top\">\n<div>\n<div>9-10<\/div>\n<\/div>\n<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"top\"><\/td>\n<td colspan=\"4\" valign=\"top\">\n<div>\n<div><\/div>\n<\/div>\n<p>&nbsp;<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"top\"><\/td>\n<td colspan=\"3\" valign=\"top\">\n<div>\n<div>Hex. nuts mixture controller to intake manifold (rubber buffer)<\/div>\n<\/div>\n<\/td>\n<td valign=\"top\">\n<div>\n<div>9-10<\/div>\n<\/div>\n<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"top\"><\/td>\n<td colspan=\"4\" valign=\"top\">\n<div>\n<div><\/div>\n<\/div>\n<p>&nbsp;<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"top\"><\/td>\n<td colspan=\"3\" valign=\"top\">\n<div>\n<div>Injection lines and fuel lines to fuel distributor (reference value)<\/div>\n<\/div>\n<\/td>\n<td valign=\"top\">\n<div>\n<div>10-12<\/div>\n<\/div>\n<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"top\"><\/td>\n<td colspan=\"4\" valign=\"top\">\n<div>\n<div><\/div>\n<\/div>\n<p>&nbsp;<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"top\"><\/td>\n<td colspan=\"3\" valign=\"top\">\n<div>\n<div>Injection lines to injection valves (reference value)<\/div>\n<\/div>\n<\/td>\n<td valign=\"top\">\n<div>\n<div>10-15<\/div>\n<\/div>\n<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"top\"><\/td>\n<td colspan=\"4\" valign=\"top\">\n<div>\n<div><\/div>\n<\/div>\n<p>&nbsp;<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"top\"><\/td>\n<td colspan=\"4\" valign=\"top\">\n<div>\n<div><strong>Special tool<\/strong><\/div>\n<\/div>\n<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"top\"><\/td>\n<td colspan=\"4\" valign=\"top\">\n<div>\n<div><\/div>\n<\/div>\n<p>&nbsp;<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"top\"><\/td>\n<td valign=\"top\">\n<div>\n<div>Torque wrench 1\/4&#8243; square, 4\u201416 Nm<\/div>\n<\/div>\n<\/td>\n<td colspan=\"2\" valign=\"top\">\n<div><img decoding=\"async\" src=\"https:\/\/mbci.mackuz.ovh\/warsztat\/silniki\/M110\/m110%20-%200491-1.jpg\" alt=\"m110 - 0491-1.jpg\" \/><\/div>\n<\/td>\n<td valign=\"top\">\n<div>\n<div>000 589 67 21 00<\/div>\n<\/div>\n<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"top\"><\/td>\n<td colspan=\"4\" valign=\"top\">\n<div>\n<div><\/div>\n<\/div>\n<p>&nbsp;<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"top\"><\/td>\n<td colspan=\"2\" valign=\"top\">\n<div>\n<div>Removal<\/div>\n<\/div>\n<\/td>\n<td colspan=\"2\" rowspan=\"2\" valign=\"top\">\n<div><img decoding=\"async\" src=\"https:\/\/mbci.mackuz.ovh\/warsztat\/silniki\/M110\/m110%20-%200491-2.jpg\" alt=\"m110 - 0491-2.jpg\" \/><\/div>\n<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"top\"><\/td>\n<td colspan=\"2\" valign=\"top\">\n<div>\n<div>1\u00a0 \u00a0 Remove air cleaner.<\/div>\n<div>2\u00a0 \u00a0Unscrew all fuel and injection lines on fuel distribu\u00adtor and on injection valves. Catch fuel with a rag.<\/div>\n<div>Close fuel feed and return line blind.<\/div>\n<div>3\u00a0 \u00a0Pull electric connecting cable, to the extend installed, from safety switch.<\/div>\n<div>4\u00a0 \u00a0Unscrew all hex. screws and both hex. nuts from mixture controller.<\/div>\n<\/div>\n<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"top\"><\/td>\n<td colspan=\"4\" valign=\"top\">\n<div>\n<div><\/div>\n<\/div>\n<p>&nbsp;<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"top\"><\/td>\n<td colspan=\"4\" valign=\"top\">\n<div>\n<div>5\u00a0 \u00a0Remove mixture controller.<\/div>\n<div>6\u00a0 \u00a0Renew air guide housing according to condition. For this purpose, loosen hose clamp on rubber sleeve and on contour hose for idle air.<\/div>\n<\/div>\n<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"top\"><\/td>\n<td colspan=\"4\" valign=\"top\">\n<div>\n<div><\/div>\n<\/div>\n<p>&nbsp;<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"top\"><\/td>\n<td colspan=\"4\" valign=\"top\">\n<div>\n<div>07.3.2 I la-200\/1 F2<\/div>\n<\/div>\n<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"top\"><\/td>\n<td colspan=\"4\" valign=\"top\">\n<div>\n<div><\/div>\n<\/div>\n<p>&nbsp;<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<table border=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"top\"><\/td>\n<td valign=\"top\">\n<div>\n<div><\/div>\n<\/div>\n<p>&nbsp;<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"top\"><\/td>\n<td valign=\"top\">\n<div>\n<div><strong>Installation<\/strong><\/div>\n<\/div>\n<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"top\"><\/td>\n<td valign=\"top\">\n<div>\n<div><\/div>\n<\/div>\n<p>&nbsp;<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"top\"><\/td>\n<td valign=\"top\">\n<div>\n<div>7\u00a0 \u00a0Mount air guide housing.<\/div>\n<div>8\u00a0 \u00a0Install mixture controller with Curil K 2 or Hylomar in vice <em>versa <\/em>sequence.<\/div>\n<div>9\u00a0 \u00a0Tighten hex. screws and hex. nuts to 9\u201410 Nm.<\/div>\n<div>10\u00a0 \u00a0Connect injection lines and fuel lines. Pay attention to tightening torques as reference values.<\/div>\n<div><strong>Attention!<\/strong><\/div>\n<div>When tightening injection lines and fuel lines, apply counterhold to injection valves as well as to double thread connections on fuel distributor.<\/div>\n<div>11\u00a0 \u00a0 Run engine and check all fuel connections for leaks.<\/div>\n<div>12\u00a0 \u00a0Adjust idle speed (07.3-100).<\/div>\n<\/div>\n<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"top\"><\/td>\n<td valign=\"top\">\n<div>\n<div><\/div>\n<\/div>\n<p>&nbsp;<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"top\"><\/td>\n<td valign=\"top\">\n<div>\n<div>07.3.2 Ila-200\/2 F2<\/div>\n<\/div>\n<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"top\"><\/td>\n<td valign=\"top\">\n<div>\n<div><\/div>\n<\/div>\n<p>&nbsp;<\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>&nbsp; &nbsp; 07.3\u2014200 Removal and installation of mixture controller &nbsp; Tightening torques Nm &nbsp; Hex. screws mixture controller to air guide housing 9-10 &nbsp; Hex. nuts mixture controller to intake manifold (rubber buffer) 9-10 &nbsp; Injection lines and fuel lines to fuel distributor (reference value) 10-12 &nbsp; Injection lines to injection valves (reference value) 10-15 &nbsp; Special tool &nbsp; Torque wrench 1\/4&#8243; square, 4\u201416 Nm 000 589 67 21 00 &nbsp; Removal 1\u00a0 \u00a0 Remove air cleaner. 2\u00a0 \u00a0Unscrew all fuel and injection lines on fuel distribu\u00adtor and on injection valves. Catch fuel with a rag. Close fuel feed and return line blind. 3\u00a0 \u00a0Pull electric connecting cable, to the extend installed, from safety switch. 4\u00a0 \u00a0Unscrew all hex. screws and both hex. nuts from mixture controller. &nbsp; 5\u00a0 \u00a0Remove mixture controller. 6\u00a0 \u00a0Renew air guide housing according to condition. For this purpose, loosen hose clamp on rubber sleeve and on contour hose for idle air. &nbsp; 07.3.2 I la-200\/1 F2 &nbsp; &nbsp; &nbsp; Installation &nbsp; 7\u00a0 \u00a0Mount air guide housing. 8\u00a0 \u00a0Install mixture controller with Curil K 2 or Hylomar in vice versa sequence. 9\u00a0 \u00a0Tighten hex. screws and hex. nuts to 9\u201410 Nm. 10\u00a0 \u00a0Connect injection lines and fuel lines. Pay attention to tightening torques as reference values. Attention! When tightening injection lines and fuel lines, apply counterhold to injection valves as well as to double thread connections on fuel distributor. 11\u00a0 \u00a0 Run engine and check all fuel connections for leaks. 12\u00a0 \u00a0Adjust idle speed (07.3-100). &nbsp; 07.3.2 Ila-200\/2 F2 &nbsp; &nbsp; &nbsp; &nbsp;<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_crdt_document":"","footnotes":""},"categories":[27,33],"tags":[],"class_list":["post-2605","post","type-post","status-publish","format-standard","hentry","category-m110","category-mechanical-gazoline-injection-system-cis"],"aioseo_notices":[],"featured_image_src":null,"author_info":{"display_name":"mackuz","author_link":"https:\/\/mbci.mackuz.ovh\/index.php\/author\/mackuz\/"},"_links":{"self":[{"href":"https:\/\/mbci.mackuz.ovh\/index.php\/wp-json\/wp\/v2\/posts\/2605","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/mbci.mackuz.ovh\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/mbci.mackuz.ovh\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/mbci.mackuz.ovh\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/mbci.mackuz.ovh\/index.php\/wp-json\/wp\/v2\/comments?post=2605"}],"version-history":[{"count":1,"href":"https:\/\/mbci.mackuz.ovh\/index.php\/wp-json\/wp\/v2\/posts\/2605\/revisions"}],"predecessor-version":[{"id":2606,"href":"https:\/\/mbci.mackuz.ovh\/index.php\/wp-json\/wp\/v2\/posts\/2605\/revisions\/2606"}],"wp:attachment":[{"href":"https:\/\/mbci.mackuz.ovh\/index.php\/wp-json\/wp\/v2\/media?parent=2605"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/mbci.mackuz.ovh\/index.php\/wp-json\/wp\/v2\/categories?post=2605"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/mbci.mackuz.ovh\/index.php\/wp-json\/wp\/v2\/tags?post=2605"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}